Safety instruction
Electrical appliances should only be ins-
talled and mounted by a qualified electri-
cian.
Accident prevention measures in force in
the country must be respected.
Failure to adhere to the installation ins-
tructions could lead to damage to the
appliance, a fire or could be a danger to
others.
Danger!
• Please observe the measures
and standards in force for SELV
electrical circuits when installing
and fitting the cables. Before
any intervention on the applian-
ce or the charge, switch off the
charging station at the circuit
breaker upstream and lockout
the appliance if necessary.
• Remember to take into ac-
count all of the circuit breakers
delivering potentially dangerous
voltages to the appliance or
charge.
• Risk of electic shock.
Introduction
Flow connects the electrical system to the
main producers and consumers of the instal-
lation in a modular way. Once installed in the
meter cabinet, flow monitors and controls the
electrical energy dynamics in your home in a
modular and flexible manner, by measuring
and controlling devices like electric storage
system, electric vehicles, heating system and
photovoltaic installation.
It prevents your domestic electrical supply
from being overloaded and optimize the
consumption and energy flows.
Technical features
Charging station
Voltage.............................................230V~/400V~
Electrical protection .................40A MCB Curve C
Current.................................................. 32A max.
Maximum Power in Mode 3..............................
.........................................7kW (1Ph) / 22kW (3Ph)
Cable section.......................................10-16 mm²
EMC
Current ................................................... 63A max.
Meter
Electrical protection
ECR140D ........................................................ 40A
ECR380D ........................................................ 80A
Recomendations
Any access to internal areas,
beyond the areas described in this
manual, is prohibited and voids
the warranty and any other form of
support.
It can be damaging to the parts
and/or to the electronic compo-
nents.
These products have been defined
so that they do not have to be
accessed during product imple-
mentation and maintenance ope-
rations.
Non-contractual document, sub-
ject to modification without notice.
a
Consignes de sécurité
Les prescriptions de prévention contre les
accidents en vigueur dans le pays doivent
être respectées.
Le non-respect des consignes d’ins-
tallation peut entraîner des dommages
sur l’appareil, un incendie ou présenter
d’autres dangers.
Danger!
• Veuillez observer les prescrip-
tions et les normes en vigueur
pour les circuits électriques
TBTS lors de l’installation et de
la pose des câbles. Avant toute
intervention sur l’appareil ou la
charge, mettre hors tension la
borne au niveau du disjoncteur
situé en amont et réaliser la
consignation si nécessaire.
• Ne pas oublier de prendre
en compte tous les disjonc-
teurs qui délivrent des tensions
potentiellement dangereuses à
l’appareil ou à la charge.
• Risque de choc électrique.
Introduction
Flow relie le système électrique aux princi-
paux producteurs et consommateurs de l‘ins-
tallation. Une fois installé de façon modulaire
dans le coffret électrique, flow surveille la
dynamique de l‘énergie électrique consommé
et produite dans votre installation, il mesure et
contrôle des appareils comme le système de
stockage d‘électricité, les bornes de recharge
pour véhicules électriques, le système de
chauffage/climatisation, la production d‘eau
chaude sanitaire et l‘installation photovol-
taïque.
Il prévient toute surcharge de votre approvi-
sionnement électrique et permet d’optimiser
la consommation et les flux d’énergie.
Caractéristiques techniques
Borne de charge
Tension............................................230V~/400V~
Protection électrique.............40A MCB Courbe C
Courant.................................................. 32A max.
Puissance de charge maximum Mode3................
.........................................7kW (1Ph) / 22kW (3Ph)
Section de câble ..................................10-16 mm²
EMC
Courant .................................................. 63A max.
Compteur
Protection électrique
ECR140D ........................................................ 40A
ECR380D ........................................................ 80A