GB
35
2.
Remove the detector from its base by turning the locking ring anti-clockwise.
3.
If the detector was part of a network, refer to 2.3 Installing a detector as part of a
network.
4.
Position the new detector on its base and turn the locking ring clockwise.
5.
Test the detector (see Testing the detector).
4.3 In case of work in the home
The detector must not be painted.
If work is to be carried out after the detector has been installed, cover it completely.
• Type of detection: optical smoke detector
• Average coverage: 50 m
2
• Use: indoor
• Power: sealed, non-replaceable lithium battery 2 x 3 V with a 10-year battery life
• Indication: - detector status
- faults
• Integrated sounding upon detection: 85 dB at 3 m
• 75 dB integrated sounding at 1 m: - during testing
- during fault indications
• Interconnection via radio: 10 detectors max.
• Operating temperature: -10°C to + 65°C
• Storage temperature: -10°C to + 65°C
• Degree of protection: IP22
• Dimensions (D x H): 116 mm x 49 mm
• Weight: 255 g
5. Technical data
IMPORTANT: do not forget to remove the protection when the work is finished.