2978 No-Touch Wave-To-Exit Switch
Installation Instructions
I-EA00062
Rev 1, Rev Date: 1/27/14
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995
Typical Wiring Examples
2978
Terminal
Block
Connecting the Switch to an Access Control Panel or Door
Operator:
Using the 2978 as a request to exit device in an access control system
To Access
Control
Panel
To 12/24VDC
Power Supply
To Auto
Operator
+
-
NO
NC C
NO
NC C
12/24VDC Relay#1 Relay#2
*
NOTE
: Refer to manufacturer’s
installation instructions for Power
Supply, Keypad, & Lock wiring.
Locks must be the same voltage as
the power supply output.
FAIL
SECURE
LOCK
+
-
FAIL
SAFE
LOCK
+
-
2915/2916
Digital Keypad
12 or
24VDC
Main
Output
(+) (-)
2908
POWER SUPPLY
Touchless Sensor Power
+
-
NO
NC C
NO
NC C
12/24VDC Relay#1 Relay#2
Terminal
Block
120V
A/C Mains
*
*
*
E 1
E 2
E 3
E 4
E 5
E 6
E 7
E 8
AUXILIARY RELAY
2 AMPS @ 28VDC MAX
+
-
KEY PAD POWER
12-24 VOLTS
AC OR DC
SENSE
GROUND
REX
GROUND
GROUND
OUTPUT 3
OUTPUT 4
GROUND
BLACK
GREEN
BLUE
BLACK
BLACK
VIOLET
BLACK
GRAY
MAIN RELAY
5 AMPS @ 28VDC MAX
NO
COM
NC
NO
NC
COM
}
}
}
2978