background image

Page 8 of 8

2916 Keypad

Installation Instructions

I-EA00080

Rev 9, Rev Date: 7/9/21

Always visit www.hagerco.com for the latest Installation Instructions

HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 • (800) 325-9995

OPTIONAL 
SHROUD

SURFACE  MOUNT

(WITH OPTIONAL SHROUD)

Part #2-679-0669

4X
Mount
at holes

POST MOUNT

(WITH SHROUD)

4"

4"

Содержание 2916

Страница 1: ...it the input can be wired to a normally open service switch or automatic timer that will disable access while the switch is closed The REQUEST TO EXIT input can be wired to a normally open pushbutton to provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to acti...

Страница 2: ...SALMON GREEN GRAY BLACK VIOLET BLACK BLUE DOOR POSITION SWITCH N C REQUEST TO EXIT SWITCH N O GROUND OUTPUT 4 OUTPUT 3 GROUND SENSE REQUEST TO EXIT GROUND E1 E8 E7 E6 E5 E4 E3 E2 C NO C NC NO AUXILIARY OUTPUTS 100mA MAX TO COMMON NOT USED KEYPAD POWER WIRE HARNESS E1 E8 MAIN RELAY AUXILIARY RELAY ANTI TAMPER SWITCH BACK JP1 E1 E8 JP2 Grn Wire To earth ground CAUTION IF THE UNIT IS AC POWERED MAKE ...

Страница 3: ...IGGERS A NORMALLY OPEN ALARM PANEL ZONE EXAMPLE 2 BLUE PINK SALMON OUTPUT 3 COM OUTPUT 4 COM POWER SOURCE OUTPUT 3 END OF LINE RESISTOR ALARM PANEL NO ZONE COMMON LOW VOLTAGE LAMP BLACK BLACK OUTPUT 4 EACH OUTPUT 100 mA MAXIMUM Wire Pigtail Wire Pigtail Fig 4 Basic Door Installation Wiring Sense Input RE Note The SENSE input gray wire can be programmed as either a door sense or inhibit input Both ...

Страница 4: ...pen Relay 2 toggled The green indicator will light momentarily when the new code is accepted The green indicator will light when the new code is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the code number i e 0001 do not need to be entered when programm...

Страница 5: ... Alarm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggled Press 15 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Request to Exit Output Default No Output Sets which output activates when the ...

Страница 6: ...the keypad STEP 2 Locate Remove jumper at JP2 Reference page 2 STEP 3 Re apply power You will get a single beep and the yellow LED will flash momentarily STEP 4 Replace jumper on JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Beep Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On t...

Страница 7: ...s visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 5 750 1 375 3 000 4X Mount at holes With supplied screws and hole expansion anchors SURFACE MOUNT MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots ...

Страница 8: ... 9 Rev Date 7 9 21 Always visit www hagerco com for the latest Installation Instructions HAGER COMPANIES 139 Victor Street St Louis MO 63104 800 325 9995 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD Part 2 679 0669 4X Mount at holes POST MOUNT WITH SHROUD 4 4 ...

Отзывы: