AC LINE CONNECTIONS FOR OVERSEAS USE
The
power transformer supplied in DH-500 amplifiers sold in multi-voltage transformer is installed. This, the 600
o h m
the USA is intended for 120 volt,
60
Hz operation only. For use resistors, the mounting hardware, and the alternate line fuse are
in other countries, a multi-voltage transformer is supplied in supplied in kits which include this transformer.
Export versions, available at higher cost. It has dual tapped The diagrams below show pictorially and schematically the
primary windings which can be connected in series or parallel alternative wiring. Only the pertinent wire connections are
combinations for 100, 120, 200, 220 or 240 volt, 50 or 60 Hz shown. There are other wires connected to the 7-lug terminal
power sources. The connections which are different from the strip which are unchanged. If the amplifier is to be operated with
standard 120 volt connections described in the kit assembly line voltages between 200 and 240 volts, a different fan, part
instructions are all related to the transformer lead terminations, #AA128, is required, the 600 ohm resistors must replace the
and to the large resistors on the 7-lug terminal strip. An 300 ohm values, and the 7 ampere slo-blo fuse must replace the
additional
3-lug terminal strip is required when the 15 ampere line fuse.
100v.
240V.
1402
K
TO PWR SW
240 V
18