Reboot button

Reboot
button

Press the reboot button to restart the lock, when the system is 

unresponsive. No user data is deleted.

Replace batteries

1.5V AA Alkaline Battery is required.Total is 8 pcs, divided

into 2 groups.

One group works for power supply, two groups is used for

longer operation time.

Do not mix old and new batteries together in replacement.

Network module

Please contact Hafele customer service center for more 

details.

Access master mode and press [ 4 ] for function extension,

which is reserved for wireless communication and other 

smart home interfaces.

Network
module
interface

Service features

Network
module

Содержание PP9000

Страница 1: ...www hafele com Model PP9000 Digital door lock The contents of this user manual are subject to change without prior notice to the user in order to enhance performance of the products PP9000 User manual ...

Страница 2: ...y 13 Reboot button 14 Replace batteries 14 Network module 14 How to change master PIN code 5 How to add user PIN code 5 How to add fingerprint 5 How to add key card 6 How to delete user PIN code 6 How to delete fingerprint 7 How to delete key card 7 Opening mode setting 8 Voice guide setting 8 Language setting 8 System query serial number 8 Network module Optionally available 9 Bluetooth setting 9...

Страница 3: ...rce the lock is suspended with alarm When the privacy function is activated the door cannot be opened from outside with user PIN code key card or fingerprint except with master PIN code Privacy function Random security coding function The random number can be added before or after the real user PIN code but the maximum length is 32 digits This feature will prevent the real user PIN code from being...

Страница 4: ... wipe with a soft cloth If there is a low battery alert please replace all the batteries in time and make sure they are properly installed 1 You can follow the voice guide by multi language English Chinese 2 Master PIN code 6 12 digits Default master PIN code is 12345678 please modify it after installation 3 User PIN code 6 12 digits Maximum capacity is 10 with user number 00 09 4 Fingerprint Maxi...

Страница 5: ...ser PIN code Input number 00 99 Input number 00 09 Enter card Touch the screen to activate lock Settings Master PIN code Opening mode setting Important First step is to set your own master PIN code Speaker Wrong code entry limit Shutdown time Voice guide language Factory defaults 12345678 Normal mode Enabled 5 times 2 mins English ...

Страница 6: ...ntered within 10 seconds 2 At any time you can return to the previous menu by pressing the key How to add fingerprints 1 When registering user fingerprint the fingerprint must be entered within 10 seconds 2 At any time you can return to the previous menu by pressing the key User Number User Type Notes 00 04 Normal User Permanent 05 08 Temporary User Invalid after using one time or in safety mode 0...

Страница 7: ... time you can return to the previous menu by pressing the key Delete access data How to delete user PIN code Delete one user PIN code 6 12 digits Delete all user PIN code Unusable in safe mode 6 12 digits 1 When deleting user PIN codes the user number must be entered within 10 seconds 2 At any time you can return to the previous menu by pressing the key ...

Страница 8: ... to delete key card 1 When deleting user card the card must be entered within 10 seconds 2 At any time you can return to the previous menu by pressing the key 6 12 digits 6 12 digits 6 12 digits 6 12 digits Fingerprint to be deleted or Key card to be deleted or 1 When deleting user fingerprint the fingerprint must be entered within 10 seconds 2 At any time you can return to the previous menu by pr...

Страница 9: ... serial number Turn off voice guide Excluding alarm and menu operation Additional lock features 6 12 digits Chinese English Normal mode Single verification means opening by PIN code fingerprint or card Safe mode Double verification means opening by PIN code fingerprint PIN code card or fingerprint card or Opening mode setting Turn on voice guide ...

Страница 10: ... door is opened properly from outside the defense mode will be disabled Network module Optionally available Log off network 6 12 digits 6 12 digits Join network Bluetooth settings Manage Bluetooth under Bluetooth turned on Enable Bluetooth 6 12 digits 6 12 digits or or Connect Bluetooth Disconnect Bluetooth Disable Bluetooth 1 The default setting for Bluetooth is disabled 2 Please enabling the Blu...

Страница 11: ... be temporary hold after closing The door will be released when user wake up the lock from outside When door is locked long press CLOSE button to switch on privacy mode Voice prompt Inside deadlock enabled only Master PIN code and mechanical key can open the door from outside User PIN code Fingerprint Card is prohibited Privacy mode Mute Voice switch Mute Voice switch Temporary setting Voice Mute ...

Страница 12: ... Enroll card 4 Delete user PIN code 5 Delete fingerprint 6 Delete card 7 Opening mode Setting 9 Change master PIN code 1 Voice guide setting 2 Language setting 1 System query serial number 1 Join network 2 Log off network Press 2 Press 3 Press 4 1 Enable Bluetooth Press 5 1 Connect Bluetooth 2 Disconnect Bluetooth 3 Disable Bluetooth Bluetooth disabled Bluetooth enabled ...

Страница 13: ... one beep sounds Voice prompt Verification Succeeded Insert the key into key hole and rotate it with proper angles Then open the door Random security coding function The random number can be added before or after the real user PIN code but the maximum length is 32 digits This feature will pervent the real user PIN code from being exposed Mechanical key Mechanical key Manual open knob Turning manual...

Страница 14: ...to locking In auto mode door will be locked automatically in 1 5 seconds after closing Manual locking In manual mode press CLOSE button to lock the door from inside or verify user fingerprint PIN code card to lock the door from outside Restore to factory default settings Reset button A M mode switch Operation instructions 1 Open the upper cover and find the reset button 2 Double click RES button t...

Страница 15: ...ded into 2 groups One group works for power supply two groups is used for longer operation time Do not mix old and new batteries together in replacement Network module Please contact Hafele customer service center for more details Access master mode and press 4 for function extension which is reserved for wireless communication and other smart home interfaces Network module interface Service featu...