17
Operation
The hood is equipped with a
“TOUCH”
device to control the
lights and speed.
For the correct use please carefully read the intructions below.
The cooker hood can be controlled through a remote control
available as accessory kit (see the paragraph relating to the
functioning of the remote control).
• Key
T1
: delays hood switching off timing the speed set
for some minutes.
By such function, when the timing is elapsed, the hood
switches off.
The timing is divided as follows:
• suction speed (power) 1:
20 minutes
• suction speed (power) 2:
15 minutes
• suction speed (power) 3:
10 minutes
• suction speed (power) 4:
5 minutes
PLEASE NOTE:
When operating the timer, the hood
might switch to a lower intake speed (power) before
turning off, as on some speeds there is already a timing
on the speed reduction itself.
When
keys
T2
and
T3
are pressed, the hood leaves the
timed function and the suction speed (power) increases
or decreases according to the key pressed. During the
timing phase the LED related to the corresponding speed
flashes.
• Key
T2:
Decreases the active suction speed (power)
(
4
Ļ
3
Ļ
2
Ļ
1
Ļ
OFF
).
The speed is displayed through the LED related to the
corresponding speed.
Key
T2
has no effect on the opening/closure of the
suction panel.
• Key
T3:
Increases the active suction speed (power)
(
1
Ļ
2
Ļ
3
Ļ
4
).
The speed is displayed through the LED related to the
corresponding speed.
Note: (only for models fitted with a motor or a remote
GME 22):
Suction speed 4 (power) is timed for 6 minutes, after
which the hood will automatically switch to suction speed
3 (power).
Note:
(
only for remote GME 88):
Suction speed 3 (power) is timed for 7 minutes, after
which the hood will automatically switch to suction speed
2 (power).
Suction speed 4 (power) is timed for 6 minutes, after
which the hood will automatically switch to suction speed
2 (power).
Note:
If the panel is closed (hood is off) key
T3
activates
the opening of the suction panel first and then sets the
hood to the suction speed (power)
1
.
• Key
T4*
: Switches on the light
Note:
If the suction panel is closed (hood is off) key
T4
activates the opening of the suction panel first and then
switches on the light.
• Key
T5:
Opens (Lifts) and closes (lowers) the suction
panel.
With the hood switched off and the panel closed, key
T5
opens the suction panel first and then sets the hood to
the suction speed (power)
1
.
With the hood switched on (at any speed) and the panel
open, key
T5
switches off the hood first (and, if they are
on, it switches off the lights as well) and then closes the
suction panel.
*
Depending on the model available.
Additional operating information
During the removal of the front panel due to cleaning and
maintenance operations, all the electronic functions of suction
and movement are locked.
Anti-pinch safety: if an obstacle obstructs the closure of the
Downdraft, the closure is stopped and the trolley goes up.
Grease Filter saturation signal.
Every 40 hours of use the hood signals the need for
maintenance of the grease filter.
The signal is by making all the suction speed LEDs (powers)
flash contemporaneously.
Reset of the grease filter signal
After carrying out the maintenance of the grease filter, press
key T1 for more than 3" in order to reset the signal.
Note: The signal is not displayed with hood switched off
(OFF), regardless of the position of the suction panel.