background image

7

phase

3

).

7.

  Introduce and screw the screws (and washer(s)) up into 

the hole(s) for the definitive fixing (

COMPULSORY!!

). 

Then, having checked the setting of the hood, TIGHTEN 
ALL THE upper and lower SCREWS.  

Note:

 the lower fixing points are visible removing the fats 

filters and they are at the sides and/or at the centre of the 
hood (after having removed the frame of the carbon filter, 
if present, in the latter case).   

 

In any case, we recommend using the lateral holes, when 
available, to increase the stability of the hood.   

8.

  Connect a tube (tube and bands for fixing not supplied, to 

be purchased) for discharging the fumes to the 
connection ring placed over the aspiration motor unit.   

 

The other end of the tube should be connected to a 
device for expelling fumes on the outside of the hood in 
the aspiration version. If you want to use the filtering 
version, fix deflector 

F

 to flues support bracket 

G

 and 

connect the other end of the tube to the connection ring 
placed on deflector 

F

.

9.

  Connect the electricity.  

10.

  Apply the flues and fix them above with 2 screws (

10a

) to 

flues support bracket 

„G“

 (

10b

).

11.

  Slide the lower section of the flue down to cover the 

aspiration set until inserting it completely into the 
apposite housing over the hood. Remount the carbon 
filter frame and the fat/s filter/s and check the perfect 
functioning of the hood. 