background image

6

filter(s) when necessary to maintain a good grease filter 
efficiency. Use the maximum diameter of the ducting system 
indicated in this manual to optimize efficiency and minimize 
noise. 

Use

The hood is designed to be used either for exhausting or filter 
version. 

Ducting version

The hood is equipped with a top air outlet 

B

 for discharge of 

fumes to the outside (exhaust pipe and pipe fixing clamps not 
provided). 

Connect the hood and discharge holes on the walls 

with a diameter equivalent to the air outlet (connection flange). 
Using the tubes and discharge holes on walls with smaller 
dimensions will cause a diminution of the suction performance 
and a drastic increase in noise. 

Any responsibility in the matter is therefore declined.  

Attention! If the hood is supplied with carbon filter, then it 
must be removed. 

Filter version

Should it not be possible to discharge cooking fumes and 
vapour to the outside, the hood can be used in the 

filter 

version

, fitting an activated carbon filter and the deflector 

F

on the support (bracket) 

G

, fumes and vapours are recycled 

through the top grille 

H

 by means of an exhaust pipe 

connected to the top air outlet 

B

 and the connection ring 

mounted on the deflector 

F

 (exhaust pipe and pipe fixing 

clamps not provided).   

Attention! If the hood is not supplied with carbon filter, 
then it must be ordered and mounted. 

Installation 

The minimum distance between the supporting surface for the 
cooking equipment on the hob and the lowest part of the 
range hood must be not less than 50cm from electric cookers 
and 65cm from gas or mixed cookers. 
If the instructions for installation for the gas hob specify a 
greater distance, this must be adhered to. 

  Electrical connection 

The mains power supply must correspond to the rating 
indicated on the plate situated inside the hood. If provided with 
a plug connect the hood to a socket in compliance with current 
regulations and positioned in an accessible area, after 
installation. If it not fitted with a plug (direct mains connection) 
or if the plug is not located in an accessible area, after 
installation,  apply a double pole switch in accordance with 
standards which assures the complete disconnection of the 
mains under conditions relating to over-current category III, in 
accordance with installation instructions. 

Warning!

 Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 
the mains cable is correctly assembled. 

Mounting

Before beginning installation: 

• 

Check that the product purchased is of a suitable size for 

the chosen installation area. 

• 

Remove the charcoal (*) filter/s if supplied (see also 
relative paragraph). This/these is/are to be mounted only 
if you want lo use the hood in the filtering version. 

• 

Check (for transport reasons) that there is no other 
supplied material inside the hood (e.g. packets with 
screws (*), guarantees (*), etc.), eventually removing 
them and keeping them. 

• 

If possible, disconnect and move freestanding or slide-in 
range from cabinet opening to provide easier access to 
rear wall/ceiling. Otherwise put a thick, protective 
covering over countertop, cooktop or range to protect 
from damage and debris. Select a flat surface for 
assembling the unit. Cover that surface with a protective 
covering and place all canopy hood parts and hardware 
in it. 

• 

In addition check whether near the installation area of the 
hood (in the area accessible also with the hood mounted) 
an electric socket is available and it is possible to 
connect a fumes discharge device to the outside (only 
suction version).  

•  Carry out all the masonry work necessary (e.g. 

installation of an electric socket and/or a hole for the 
passage of the discharge tube). 

Expansion wall plugs are provided to secure the hood to most 
types of walls/ceilings. However, a qualified technician must 
verify suitability of the materials in accordance with the type of 
wall/ceiling. The wall/ceiling must be strong enough to take 
the weight of the hood. 

Do not tile, grout or silicone this 

appliance to the wall. Surface mounting only. 

The electric connection box must be assembled as shown in 

Fig. A-B-C

.

Fig. 5 
1.

  Drawing a line on the wall with a pencil up to the ceiling, 

corresponding to the centre line, will make the installation 
operations easier. 

2.

  Apply the perforation diagram to the wall: the vertical 

centre line printed on the perforation diagram should 
correspond to the centre line drawn on the wall. In 
addition, the lower edge of the perforation diagram 
corresponds to the lower edge of the hood.  

3.

  Make holes as indicated on the template, insert the wall 

dowels and screw 2 screws into the upper holes, leaving 
a space of about 1 cm between the head of the screw 
and the wall. 

Note:

 Always make the holes indicated on the template. 

The upper 2 are for hooking the hood up while the lower 
holes (generally 1 central or more lateral) are for the 
definitive and safety fixing.  

4.

  Apply flues support bracket 

„G“

 to the wall touching the 

ceiling. Use the flues support bracket as a perforation 
diagram (the small slot in the support must coincide with 
the line previously drawn on the wall, if present), and 
mark two holes with a pencil. Make the holes and insert 2 
dowels.  

5.

  Fix the flues support bracket to the wall with 2 screws. 

6.

  Hang the hood to the two upper screws (see installation 

Отзывы: