3.4 Factory settings
3.5 Accessories
4. Mounting and installation
The installation instructions for the system components can be found in separate documents.
They can be obtained under the respective catalogue number at: www.hafele.com
Please pay attention to the following points when installing the system:
Parameter
Value
Open time (duration of unlocking period in latchbolt lock operation)
• The open time can be set to up to 30 seconds at one second intervals
in stand-alone operation
8.5 Adjusting the open time, page 69
.
• The open time can be extended to beyond 30 secs using the MDU
110 with special functions or macros.
3 seconds
Lock type
Latchbolt lock operation
Locking function
Keyed alike
Accessories
Description
Programming key card
• Card for granting access authorisations
Clearing key card
• Card for clearing access authorisations
User key
• Electronic key
• Different designs are possible:
key card, key tag, key fob, key wristband
Macros
• On request
W
ARNING
Risk of life-threatening electric shock during assembly and installation work
when the power plug is plugged in
The system must be currentless for the entire assembly and installation process.
• Never connect the power plug to the socket during assembly and installation.
The environmental conditions in the place of installation – for example, magnetic fields
or metal materials – may impair the functionality of the system.
• Ensure that the system is installed in a suitable location.
• Set up a sample installation in the chosen location and test it out prior to carrying
out the final installation.
After completing the assembly and installation work, do not plug in the power plug or
the Powerbank. Connecting the system to the power supply launches the
commissioning process automatically.
• Read chapter
before connecting the power plug for the
first time.