Symptom
Possible Cause
Possible Solution
1. Poorly adjusted return spring.
2. Worn return spring.
1. Shorted/disconnected wiring.
1. Table locked.
2. Drive selector not engaged.
3. Sheared pin.
4. Gears not meshing or teeth missing.
5. Motor shaft and gear shaft not engaged
1. Rapid micro switch is stuck.
2. V.R. does not work properly.
3. Wiring harness unplugged from circuit
board
1. DRO is not turned on/plugged in.
2. Shorted/disconnected wiring/plugs..
1. Initial reading is incorrect.
2. Sensor has gone bad.
3. Spacing between sensor & scale is incorrect.
1. Power not turned on.
2. Bulb is burned out.
3. Short in wiring or wired incorrectly
1. Increase return spring tension.
2. Replace return spring
1. Inspect wiring connections. Replace/repair as
necessary.
1. Unlock table locks.
2. Select speed, engage drive selector.
3. Replace pin.
4. Check gears and adjust/replace.
5. Replace clutch.
1. Lightly tap on it to lower it.
2. Test/repair/replace
3. Reconnect wiring harness.
1. Press DRO ON/Power button/plug in.
2. Inspect circuit boards, sensors, plugs, and wiring
connections. Replace/repair as necessary.
1. Tare/zero/reset DRO at beginning point.
2. Test/replace sensor as necessary.
3. Adjust spacing between sensor and scale
1. Press switch/button on lamp or control panel.
2. Replace bulb.
3. Trace and test wiring. Fix any errors.
Spindle does not
fully retract.
Spindle switch does
not work.
Powerfeed does
not move table or is
slipping.
Operates at high
speed only or is
inconsistent.
DRO does not give
reading.
DRO reading is
incorrect.
Lamp will not light.
Power Feed
Digital Readout Unit (DRO)
Lamp
Page 29
Instructions Manual for BM-23A (M595D)
12/02/2018
Содержание BM-53VE
Страница 30: ...30 OPERATION MANUAL BM 23A BELT DRIVE HEAD Page 30 Instructions Manual for BM 23A M595D 12 02 2018...
Страница 33: ...33 OPERATION MANUAL Spindle Assembly Page 33 Instructions Manual for BM 23A M595D 12 02 2018...
Страница 37: ...37 OPERATION MANUAL BM 53VE Upper Head Parts List Page 37 Instructions Manual for BM 23A M595D 12 02 2018...
Страница 41: ...41 OPERATION MANUAL Base Assembly Page 41 Instructions Manual for BM 23A M595D 12 02 2018...
Страница 44: ...44 OPERATION MANUAL Lead Screw Assembly Page 44 Instructions Manual for BM 23A M595D 12 02 2018...