Fusion Quick Start Guide
Approved Document Ref: UI-FBU-03 Issue 4.1
26
OPERATING
LCD Display
The LCD displays event information, status information, and the option menus. It has two lines of text,
The LCD displays event information, status information, and the option menus. It has two lines of text,
each with 40 characters , and is backlit when there is an active event on the system or the menu options
each with 40 characters , and is backlit when there is an active event on the system or the menu options
are accessed. In the normal operating mode the backlight is dim and the top line displays a default text
are accessed. In the normal operating mode the backlight is dim and the top line displays a default text
message or user-de
fi
ned text. The second line displays the current time and date, e.g.
message or user-de
fi
ned text. The second line displays the current time and date, e.g.
The display shows the event type, i.e. Fire, the zone that the activated device is in, i.e. zone 3, the number
The display shows the event type, i.e. Fire, the zone that the activated device is in, i.e. zone 3, the number
of events and event number, i.e. 01 of 01 and the device location text
of events and event number, i.e. 01 of 01 and the device location text
Pressing button [1] reveals further device information such as type,
Pressing button [1] reveals further device information such as type,
i.e manual call point, address number and time and date of the event.
i.e manual call point, address number and time and date of the event.
This button will function without the need to activate controls.
This button will function without the need to activate controls.
NOTE : Fault conditions on the system are suppressed when Fire events
NOTE : Fault conditions on the system are suppressed when Fire events
are present, except sounder or remote faults. The GENERAL FAULT LED is
are present, except sounder or remote faults. The GENERAL FAULT LED is
illuminated and faults can be viewed if required via the ‘View Active Faults’
illuminated and faults can be viewed if required via the ‘View Active Faults’
option - when button [1] is pressed.
option - when button [1] is pressed.
In the normal operating mode only the green Supply Present LED should be illuminated. The LCD should
In the normal operating mode only the green Supply Present LED should be illuminated. The LCD should
be displaying the company name (if programmed) and the current time and date.
be displaying the company name (if programmed) and the current time and date.
Other messages that may be displayed on the LCD during normal operation are:
Other messages that may be displayed on the LCD during normal operation are:
When an event occurs, the backlight is activated and the LCD displays the event details, e.g.
When an event occurs, the backlight is activated and the LCD displays the event details, e.g.
FUSION PANEL
SYSTEM NORMAL WED 15:56 27/07/11
FIRE PANEL 01 ZONE 003 01 OF 01
STAFF ROOM
1
3
7
9
0
MENU
EVACUATE
SILENCE/
RESOUND
ALARMS
CONTROL
PANEL
RESET
MENU
MUTE
BUZZER
DEVICE
INFO
CONTROLS ACTIVE
If the keyswitch is in the ON position or the activate code has been
entered on the keypad. The code entry activation will time out after
two minutes and the panel will return to normal mode.
DELAYED
Is displayed if any output delays have been programmed.
GENERAL DISABLEMENTS
Is displayed if any zones or devices have been disabled or isolated.
Details of disablements can be viewed in MENU item: View Active
Disablements.
TEST MODE
Will show if the engineers test mode has been set to areas on the
system. Test mode should only be used by authorised personnel.
PRECINCT ACTIVE
Remote input to sound alarms is active.
ALERT ACTIVE
Remote input to pulse alarms is active.