English
6
Instructions for use
WARNING:
If you do not install and tighten the safety screw, washers, nut and
safety pin correctly, there is a risk that the fan will fall.
Electrical connections
Carry out electrical connections according to the diagram shown and described
below.
-
BROWN wire “LIVE”: motor phase
-
BLUE wire “NEUTRAL”: common neutral for motor
- GREEN / YELLOW wire: Grounding, corresponding to the symbol .
NOTE: The colour of cables in the electrical installation may vary.
Install the 5-speed wall control
Connect the wires to the fan and those coming from the ceiling with terminal
block according to the wiring diagrams provided below: the fan is controlled by
wall control switch.
Mounting rod
Green (Earth) in case of
not having this cable in
your electrical installation,
connect to electrical box.
Brown (Live)
Blue (Neutral)
Wall Control
Power supply
Live
Neutral
Connection
to fan