Safety instructions

 

Cleaning and disinfection 

After every treatment please carry out the following steps: 
 

Remove the rotating tool (e.g. bur, capper, etc.) first. Then handle the cleaning 
of the tool according to the instructions of it`s manufacturer. 
 
Remove  tissue  remains  by  wiping  off  the  unit  with  a  mildly  moistened  paper 
cloth.  Afterwards  clean  all  surfaces  with  disinfection  cloth  (e.g.  Mikrozid  AF 
Tücher of Schülke and Mayr).  
 
The charging unit is only to be cleaned with a dry cloth.  

 

Содержание Xantos

Страница 1: ...Manual Xantos Art No 0897 0898 FB 04 280 Rev 1 Art no 0897 0898...

Страница 2: ...tions 3 Cleaning Disinfection 7 Getting to know the unit 8 Before the use 9 Area of application 9 Installation site location 9 Maintenance Care 11 Cleaning the chuck 11 Handling details 12 Troubleshoo...

Страница 3: ...extracted air can escape well Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely in your hand To avoid the risk of electrocution only connect the d...

Страница 4: ...tion or spray technique Wear a nose and mouth protection Always follow the safety instructions provided by the manufacturer of the materials being formed and used For safety reasons wear goggles durin...

Страница 5: ...Before using the equipment assure that the tool can be pushed far enough into the chuck Test this with a dipstick and clean the handpiece if necessary the inserted tool sits properly in the chuck and...

Страница 6: ...ly to be accomplished by an authorized specialist The mains cable may also only be changed by the manufacturer or an authorized specialist Never remove the housing especially not while the equipment i...

Страница 7: ...capper etc first Then handle the cleaning of the tool according to the instructions of it s manufacturer Remove tissue remains by wiping off the unit with a mildly moistened paper cloth Afterwards cle...

Страница 8: ...8 Getting to know the unit 1 Speed display 2 LED shines during left rotation 3 Increase speed 4 change directory 5 decrease speed 6 on off button 8...

Страница 9: ...ental technique laboratory Milling trimming and polishing work at plaster casts and models Do not use this unit for dentist purposes i e working directly on the patient Industry Grinding milling and p...

Страница 10: ...th a diameter of 2 35 mm this is the diameter usually used for tools in podiatry To open the chuck push the spanner forward with your thumb and leave it there Now insert the tool as far as possible Pu...

Страница 11: ...To assemble the chuck follow the steps in reverse order Make sure that the chuck is opened during the assembly the handpiece button must be in forward position and is firmly applied afterwards Cleani...

Страница 12: ...hen you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ball bearings and the motor could...

Страница 13: ...if it is bent Chuck is dirty Clean the chuck according to the instructions in the manual Bur does not clamp or does not spin Chuck is not tightened well Tighten the chuck firmly according to the inst...

Страница 14: ...relates are conform to the following standards or normative documents 2014 30 EU directive EMC 2014 35 EU low voltage directive hadewe GmbH Grambartstra e 10 30165 Hannover Germany Symbols Caution Im...

Страница 15: ......

Страница 16: ...hadewe GmbH Grambartstra e 10 30165 Hannover Germany info hadewe de www hadewe de...

Отзывы: