Use 

Clamping the tool/ bur 

The  handpiece  is  equipped  with  a 
chuck,  which  can  hold  all  burs  with 
a  diameter  of  2.35  mm  (this  is  the 
diameter  usually  used  for  tools  in 
podiatry).  To  open  the  chuck,  push 
the  knob  forward  with  your  thumb 
and  leave  it  there.  Now  insert  the 
tool as far as possible. Pull back the 
knob  and  the  tool  will  be  firmly 
clamped 
 

 

 

For  security  reasons,  only 
change  the  tool,  if  the 
handpiece is turned off. 

 

Setting up the speed 

Hold  the  handpiece  (incl.  tool)  in 
your  hand  or  store  it  in  the  hand-
piece holder attached to the side of 
the control unit. 

Switch  on  the  unit  with  button 
(9).  Now  you  can  also  set  the 
speed  with  buttons  (3)  and  (4), 
and  choose  its  direction  of  rota-
tion with button (6)

 

 

 
 

 

When 

the 

device 

is 

brought  out  of  standby 
mode  it  will  run  with  the 

rotation speed and suction power 
used  last.  Take  care  to  not  start 
the mill at an overly high rotation 
speed.  Select  the  required  rota-
tion  speed  before  changing  the 
milling tool.

 

 
Foot switch (Art. 0970) 

 
Commencement of foot switch  

Only  use  the  original  hadewe  foot 
switch  to  avoid  damages.  Insert  the 
plug  of  the  foot  switch  into  the  socket 

with this symbol: 

 

 

Function of the foot switch 

If you press the foot switch for a 
longer period, you will switch on / 
off the complete control unit.

Содержание Veloria

Страница 1: ...Manual Veloria Art No 0975 FB 04 267 Rev 2 Date 02 06 2016 ...

Страница 2: ...ioning 12 Suction 14 Changing filter bag 14 Changing control unit filter 14 Clamping the bur tool 15 Setting up the speed 15 Foot switch 15 Maintenance Care Cleaning the chuck 16 Maintance overview 17 Handling instructions 17 Troubleshooting 19 Technical data 20 Declaration of conformity 20 Disposal 21 Symbol 22 Safety check 23 Accessories 23 ...

Страница 3: ...s product to someone else please include this document as it includes important infor mation on how to correctly use the product Short description of functions The Veloria is a device for the treatment of callus and nails The handpiece is compa tible with rotating tools such as diamond polishers steel cutters and ceramic cutters These can reach at speeds up to 40 000 rpm and therefore provide an e...

Страница 4: ...levant regulations Set up the unit in such a way that the air slits are not blocked and the extracted air can es cape well To avoid the risk of electrocution only connect the device to the mains power supply If you pull the power plug it will stop the connection to the mains power supply Set up the unit so that the power plug is always accessible The power switch should also always be easily acces...

Страница 5: ...w the safety instructions provided by the manufacturer of the materials being formed and used For safety reasons you must always wear disposable gloves and protective glasses when operating this unit In addition a face mask conforming to EN 14683 type IIR or EN 149 FFP 2 must also be worn When changing the filter it is advisable to wear a face mask conforming to EN 14683 type IIR or EN 149 FFP 2 E...

Страница 6: ...the tool while the motor is running Switch off the unit immediately if the bur comes off during the treatment itself the motor blocks during the treatment While doing any foot care only operate the unit with the suction turned on Only use the suction function if you have installed the suc tion filter Check this filter every 10 operating hours If it is full please exchange it A filter should be exc...

Страница 7: ...rk yourself This is only to be accomplished by an au thorized specialist The mains cable may also only be changed by the manufacturer or an authorized specialist Maintenance records may be supplied to repair workshops and trained technicians upon request Never remove the housing especially not while the equipment is plugged into the socket since some components are under electric voltage Any unaut...

Страница 8: ...on please adhere to the cleaning and disinfection instructions provided be low After every treatment please carry out these steps Remove the rotating tool e g bur first To do so pay attention to the instructions of its manufacturer Remove clothing remains through wiping off easily the unit with a moistened paper cloth Afterwards clean all surfaces with a disin fection cloth e g Mikrozid AF cloths ...

Страница 9: ...t 2 Increase the suction output 3 Reduce the speed 4 Increase the speed 5 Display of speed suction level 6 Change direction of rotation 7 LED ON during reverse rotation 8 Main switch 9 Switching ON OFF the unit Standby 10 Connecting socket for foot switch 1 2 3 4 5 6 7 8 9 10 ...

Страница 10: ...e Milling trimming and polishing Attention The suction must be in operation during foot care Manicure Grinding milling and polishing works The devise is determined of operating rotating instruments which will not penetrate the skin or murcous membrane if used appropriate but could evoke damages accidently Caution In the area of pedicure you have to work with suction techniques Operation The workin...

Страница 11: ...dust filter are correctly fitted Ensure that the tool is fixed On the left side of the device you will find the main power switch Press this switch to turn the unit on Take up the handpiece Should the handpiece be twisted by the hose you can adjust that at the con trol unit To use the hand piece and suction function press the button 9 on the front of the unit ...

Страница 12: ... corundum sanders in terms of effi ciency Working anti clockwise can be beneficial if for example the dust obscures your field of vision when working clockwise Using buttons 1 and 2 you can adjust the intensity of the suction Frequently used rotation speeds and suction power settings can be saved First select the desired rota tion speed and suction power After choosing a rotation speed and suc tio...

Страница 13: ...13 Use Work positioning The following images are examples of how to work on various parts of the foot Always make sure that the foot is firmly gripped and that you can work freely and without strain ...

Страница 14: ...14 Use ...

Страница 15: ...o EN 14683 type IIR or EN 149 FFP 2 Only operate the unit with a suction filter assembled Control the bag after every 10 operating hours Ex change a full filter bag immediately A filter should be exchanged at least after 50 operating hours At first unfold the paper of the mi cro filter Art No 5179 bag and push your finger into the opening in the front Pull out the lid of the dust chamber and remov...

Страница 16: ...tached to the side of the control unit Switch on the unit with button 9 Now you can also set the speed with buttons 3 and 4 and choose its direction of rota tion with button 6 When the device is brought out of standby mode it will run with the rotation speed and suction power used last Take care to not start the mill at an overly high rotation speed Select the required rota tion speed before chang...

Страница 17: ...nscrew the chuck To assemble the chuck follow the steps in reverse order Make sure that the chuck is opened during the assembly the handpiece button must be in forward position and is firmly applied afterwards Cleaning the chuck Soak the chuck in ethyl alcohol or a special cleaning liquid for tools Clean the slits and the hole of the chuck with a dry scrubber or brush Rinse the chuck very well and...

Страница 18: ... rust In cases in which a rust infestation was found within the handpiece thorough inspections and examinations always have proved that the rust had a foreign origin which was usually caused by the tools used in these circumstances Even in high grade steel instruments of well known manufacturers formation of rust can appear e g through wrong treatment with chemical cleaning and disinfection liquid...

Страница 19: ...an in the long run In case of sending the de vice by mail remove the dust filter before Only suck up dust or milling waste never suck up larger particles such as small bits of cotton wool as this may be get caught in the handpiece and lead to blockages Always working with maxi mum speed might have a similar effect Please make sure that the speed setting you use is according to the work you are doi...

Страница 20: ... manual Knob of the handpiece can not be moved easily Chuck is dirty Clean the chuck according to the instructions in the manual Rubber under the knob is tilted turn rubber about 90 Unit does not work at all Check if the main switch of the unit is turned on at the side of the unit Footswitch is used constantly or faulty Pull out the socket of the foot switch to see if this is the cause Pull out th...

Страница 21: ...mp 10 C to 26 C Rel humidity 25 to 75 not condensed Air pressure 700 hPa to 1060 hPa Storage Temp 5 C to 55 C Rel humidity 10 to 95 not condensed Air pressure 500 hPa to 1060 hPa Transport up to 4 weeks Temp 5 bis C 55 C Rel humidity 10 to 95 not condensed Air pressure 500 hPa to 1060 hPa Operating time The device is designed for extend ed usage Declaration of conformity We declare under our sole ...

Страница 22: ...WEEE Reg Nr DE20392713 b2b device For disposal of this unit out of Germany please contact the site where you bought this hadewe product Note for the disposal of the device treatment system Wear protecting gloves of the class 2 in accordance with DIN 374 2 during the disassembling of the device Also wear a protective mask for your face according EN 14683 version IIR or EN 149 FFP2 Disposal of dust ...

Страница 23: ...er and upper temperature limit Air pressure permissible range Air humidity permissible range Keep dry ON OFF button standby no disconnection from main power supply Change direction Suction Rotation Alternating current Direct current Safety fuse Type B applied part Socket foot switch Class II Date of manufacture ...

Страница 24: ...he regulations of the country where the device is used The inspec tion interval is once a year Accessories Art No 5179 Micro filter 3752 filter 0970 Foot switch The clamping system is designed for rotating instruments which have a shaft of 2 35mm in accordance with ISO EN ISO 179 1 ...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...hadewe GmbH Grambartstraße 10 30165 Hannover Germany info hadewe de www hadewe de ...