Before First Use 

Please read through the instructions 
carefully  before  using  the  unit  and 
carefully  note  the  safety  advice. 
Always keep this manual accessible 
to any users of the drill. 

Area of Application 

This device should only be used by 
people who have completed a foot-
care  qualification.  Before  use  the 
operator  should  make  themselves 
familiar  with  the  device  by  reading 
this  manual  or  being  instructed  by 
another. 
 
The  device  must  only  be  used  in 
closed  spaces.  It  may  be  used  in 
hospitals,  in  a  commercial  environ-
ment  or  in 

patient’s 

homes.  The 

device  is  not  intended  for  use  in 
operating rooms. 
 
The  control  unit  can  be  set  up  in  a 
cabinet, or can be used as a porta-
ble  unit  (e.g.  in  a  carry  case).  It  is 
suitable for the following scopes: 

 foot  care  (milling,  trimming  and 

polishing), 

 manicure  (grinding,  milling  and 

polishing works). 

 

The  device  is  determined  of 
operating  rotating  instru-
ments, 

which 

will 

not 

penetrate  the  skin  or  murcous 
membrane  if  used  appropriate,  but 
could evoke damages accidently. 
 

Caution:  In  the  area  of 
pedicure  you  have  to  work 
with suction techniques. 

Operation 

The  working  area  must  conform  to 
the conditions described. Set up the 
unit in such a way, that the air slits 
are  not  blocked  and  the  extracted 
air  can  escape  well.  To  guarantee 
unhindered  air  flow  there  must  a 
gap of at least 12cm to the right of 
the  device.  Position  the  device  so 
that  the  operating  buttons  are  easy 
to  reach  and  the  outlet  of  the  hose 
is  a  maximum  distance  of  60cm 
fr

om  the  patient’

s  foot.  The  unit 

should  be  placed  30  -  90cm  above 
the floor.

 

 

 

 
Image:  Example  of  positioning  of  footcare  unit 
in treatment room 

 

 

 
Image: Bird's-eye view of work area 

 

Содержание Medeas

Страница 1: ...Art 0980 0981 FB 04 288 Rev 2 Date 23 01 2019 Manual Medeas ...

Страница 2: ...edeas Plus 17 Clamping the Tool Bur Medeas Chrome 17 Adjusting the Speed 17 Memory Keys 18 Foot Switch 18 Switsch on the Handpiece Medeas Plus 18 Select Menu 19 Help Menu 19 Settings Menu 20 Confirm Filter Change 20 Turn Light ON OFF Medeas Plus 20 Pictures Videos 21 Messages 24 Maintenance Care 25 Cleaning the Chuck Medeas Plus 25 Cleaning the Clamping System Medeas Chrome 26 Upload Firmware 27 M...

Страница 3: ... and nails The handpiece is compatible with rotating tools such as diamond polishers steel cutters and ceramic cutters These can be worked with up to a speed of 30 000 rpm Medeas Chrome respectively 40 000 rpm Medeas Plus thus providing an efficient way of removing tissue The direction of rotation can be changed by pressing a button The integrated filtered suction function effectively sucks up any...

Страница 4: ...e if they have been given supervision or instruction concerning use of the appliance in a safe way and under stand the hazards involved Children should be supervised not to play with the appliance Cleaning and user maintenance shall not be made by children without supervision To avoid the risk of electrocution only connect the device to the main power supply If you pull the power plug it will stop...

Страница 5: ...center Prevent your hair from wrapping itself around moving parts If applicable wear a hair net When working with materials which might cre ate dust or moisture use a drilling unit with suc tion or spray technique Wear a nose and mouth protection Always follow the safety instructions provided by the manufacturer of the materials being formed and used For safety reasons you must always wear dis pos...

Страница 6: ...equipment assure that the tool can be pushed far enough into the chuck test this with a dipstick and clean if neces sary the inserted tool sits properly in the chuck and will not cant jam while clamping it the tool is approved for using it at the max speed see manufacturer s instructions or only use the speed required by the instru ment the tool is absolutely dry For safety reasons do not change t...

Страница 7: ... particles of liquids Always follow the operating instructions Do not carry out any repairs modifications or mainte nance work yourself This is only to be accom plished by an authorized specialist The mains cable may also only be changed by the manu facturer or an authorized specialist Mainte nance records may be supplied to repair work shops and trained technicians upon request Never remove the h...

Страница 8: ...t will run with the rotation speed and suc tion power used last Take care to not start the mill at an overly high rotation speed Select the required rotation speed before changing the milling tool In case the touch display shows a damage or does not work properly the device may not be used any longer Please send it to a qualified service workshop for repair ...

Страница 9: ...After every treatment please carry out the following steps Remove the rotating tool e g bur capper etc first Then handle the tool according to the instructions of its manufac turer Remove tissue remains by wiping off the unit with a mildly moistened paper cloth Afterwards clean all surfaces with dis infection cloth e g Mikrozid AF Tücher of Schülke and Mayr There is no limit to the number of times...

Страница 10: ...essed switch unit off standby 5 speed display 6 time 7 date 8 changing the direction of rotation left right switch 9 maintenance required 10 USB stick plugged in green light 11 Medeas Plus light yellow when switched on 12 13 14 memory keys for speed suction 15 suction stage set 16 bringing up menu with additional functions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ...

Страница 11: ...or the following scopes foot care milling trimming and polishing manicure grinding milling and polishing works The device is determined of operating rotating instru ments which will not penetrate the skin or murcous membrane if used appropriate but could evoke damages accidently Caution In the area of pedicure you have to work with suction techniques Operation The working area must conform to the ...

Страница 12: ... display prompts you to set the device language This is followed by 5 other pages with important clues With con tinue you proceed to the next page On the last page press to start the device The counter for calculat ing the maintenance proposal will automatically be set to zero The display will shut down now and the unit is in standby Take the handpiece in hand If the hose is twisting the handpiece...

Страница 13: ...esulting milling dust is swirled in a clockwise direction in the field of view Now switch to suction By means of the icon 15 you can adjust the strength of suction Frequently used speed and suction capacity can be saved First set the desired speed and suction Save this by pressing one of the three memory keys 12 13 or 14 for 4 seconds To recall the stored speed and suction power quickly briefly pr...

Страница 14: ...14 Usage Work Positioning The following images are examples of how to work on various parts of the foot Always make sure that the foot is firmly gripped and that you can work freely and without strain ...

Страница 15: ...15 Usage ...

Страница 16: ...hours Ex change a full filter bag immediately A filter bag should be exchanged at least after 50 operating hours At first unfold the paper of the filter bag art 5179 and push your finger into the opening in the front Pull out the lid of the dust chamber and remove the old filter Hold the filter in the middle to prevent it from bending and sliding off Therefore you avoid it from coming off again It...

Страница 17: ...he tool if the handpiece is turned off Clamping the Tool Bur Medeas Chrome Clamp the tools bur only when the handpiece is not working Insert the tool bur until it stops Ones can use all tools burs which has a shaft according to DIN EN ISO 1797 1 with a diameter of 2 35 mm For security reasons only change the tool if the handpiece is turned off Adjusting the Speed Take the handpiece with tools in t...

Страница 18: ...er can be switched ON OFF Briefly press the left memory key 12 to recall the speed suction Another quick press of the central lock key 13 will recall the speed suction Another quick press of the first memory key 12 can also be used This only work with tools that are approved for the 12 to 14 stored speeds When the display is switched off you can turn it on by keeping the foot switched pressed keep...

Страница 19: ...for setting the time date and language By means of this button you can return to the previous menu Help Menu Manual Here is a short form of the manual This does not replace the original manual in paper form as the latter contains more detailed instructions and safety instructions Insert Burs this clip demonstrates the clamping of rotary tools Clean Chuck video clip that demonstrates the cleaning o...

Страница 20: ...tivated Confirm Filter Change Every 50 hours of operation you will get the message to Check filters After the filter change the following must be entered into the instrument On the start screen click the icon for the select menu Then click Change Filter Confirm the filter change with YES Turn Light ON OFF Medeas Plus To turn the light on or off click the top of the bar on the light icon Alternativ...

Страница 21: ...maximum of 100 files may be located in the directory for the image viewer Click Picture Video in the select menu to start the viewer File list Scrollbar Thumbnail Reset In the file list you can see the files from the USB stick By scrolling down you can browse through the list Select an image and a small preview is shown on the right Click on thumbnail to enlarge it Click once more on the enlarged ...

Страница 22: ...eo library we provide a program ready to convert your own videos from other formats to EMF format Open the file to begin installation Follow the instructions on the monitor The conversion program to be used is File Converter Input Select a source file The following formats are supported MP4 WMV The source files should be proportionate to 4 3 to be taken so as to avoid distortion when converting Ou...

Страница 23: ...ive in order to consider the devices In the video library you can find videos and pictures that help you to explain the treatment to your customers Especially new customers are often unse cure because they do not know what to expect during a treatment It is helpful to explain the treatment steps to the patient This is often difficult especially when the patient cannot see the treatment site Pictur...

Страница 24: ...Tapping this icon will display the following message In this case contact your distributor or repair shop REMINDER CHECK FILTER Every 50 hours of operation in the suction mode you will receive the message Please change fil ter You will find instructions in the chapter Exchange Micro Filter and a help video under the menu item Help SHUTDOWN DUE TO SPEED DIFFERENCE The device switches off when the s...

Страница 25: ...sh For opening the chuck push the button forward Set the screw spanner wrench on the axle and hold it tight Now use the front of the second spanner to unscrew the chuck To assemble the chuck follow the steps in reverse order Make sure that the chuck is opened during the assembly the handpiece button must be in forward position and is firmly applied afterwards How to clean the chuck Soak the chuck ...

Страница 26: ...tem This may cause that instruments can no longer be inserted deep enough and that a tight grip is no longer granted The result of this often is abrasive wear and therefore the clamping system is to be cleaned every 50 hours of operation For this purpose screw off the pro tective sleeve of the handpiece Clean the inside of protective sleeve and the hull with a dry scrubber or brush Now insert care...

Страница 27: ...ay during the update This process takes approximately 15 minutes Never turn off the device during the update Other wise it could be damaged 5 As soon as the last line Please restart device is displayed the update is complete and you can switch the device off using the power switch 6 The device can now be used again as normal Maintenance Overview What has to be done How often Done by whom cleaning ...

Страница 28: ...s of the handpiece in form of rust bloom and causes pitting Therefore when you not working with the handpiece always remove the tool bur from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ballbearings and the motor could be damaged by this Only work with tools which are flawless Do not work with tools which are bent or out of balance whose shaft is...

Страница 29: ...oved easily Chuck is dirty Clean the chuck according to the instruc tions in the manual Rubber under the knob is tilted Turn rubber about 90 Unit does not work at all Check if the main switch of the unit is turned on at the side of the unit Footswitch is used constantly or faulty Pull out the socket of the footswitch to see if this is the cause Pull out the mains plug to reset the device The unit ...

Страница 30: ...ure 500hPa to 1060hPa 0981 Medeas Chrome control unit total weight 2 7kg dimension W273xH142xD186mm input 100V 240V AC voltage 50 60Hz power consumpt 1A 100V 0 5A 240V fuse primary F1 F2 4A delay action fuse fuse Sec Thermal fuse protection class I accuracy of speed display 10 handpiece weight 140g diameter 19 25 mm length 118 mm speed 6000 30000 rpm Accessories Spare Parts art 0970 footswitch 375...

Страница 31: ...ing the disassembling of the device Also wear a protective mask for your face according EN 14683 version IIR or EN 149 FFP2 Disposal of filter The filter bag and the control unit filter are considered low contami nated waste Dispose those in intransparent liquid tight resistant plastics sacks and do not dispose them compressed in the regular household garbage Symbols Caution Important note Follow ...

Страница 32: ...hadewe GmbH Grambartstraße 10 30165 Hannover Germany info hadewe de www hadewe de ...

Отзывы: