art. 6231, 6232, 6233, 6234 
FB 04-279 Rev. 0 
Date: 11.02.2019 

 

 

 
 
 
 

Manual 

 

 

 

 
 
 

g - file 

 

Содержание g-file

Страница 1: ...art 6231 6232 6233 6234 FB 04 279 Rev 0 Date 11 02 2019 Manual g file ...

Страница 2: ...2 Index of Contents Safety Instructions 3 Application 7 Handling Instructions 8 Troubleshooting 9 Exploded Drawing 10 Technical Data 11 ...

Страница 3: ...nd the hazards involved Children should be supervised not to play with the appliance The installation of the working area has to correspond to the relevant regulations Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely in your hand Prevent any liquids from entering into the control unit since this could damage the electronic elements Clean the o...

Страница 4: ...r comes off during the treatment itself the motor blocks during the treatment Turn on the unit only when you hold the handpiece safely in your hand or if it is placed in the handpiece holder Ensure that the patient s foot and the handpiece are held firmly in place during the operation To prevent injury work with extreme caution on the foot of the patient and use only light pressure To ensure that ...

Страница 5: ... max speed see manufacturer s instructions or only use the speed required by the instrument the tool is absolutely dry After each use and before each new customer The tools are to be cleaned disinfected and sterilized Caution Handpiece and motor may not be sterilized All surfaces of the handpiece are disinfected Take care that no liquids enter the handpiece Always follow the operating instructions...

Страница 6: ...especially not while the equipment is plugged into the socket since some components are under electric voltage Any unauthorized or improper handling e g trying to repair the unit of the equipment will immediately nullify the guarantee warranty and any other liabilities of the manufacturer ...

Страница 7: ... ring B clockwise until it snaps in Now the clamp is open Insert the bur all the way to the stop Turn ring B counter clockwise until it snaps in Check that the bur is clamped correctly and cannot be pulled out You may never turn on the unit while the chuck is open This may cause damages at the motor and the electronic For security reasons only change the tool if the handpiece is turned off Adjusti...

Страница 8: ...t with chemical cleaning and disinfection liquids This extraneous rust affects internal parts of the handpiece in form of rust bloom and causes pitting Therefore when you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ball bearings and the motor could be damaged by this Only work with to...

Страница 9: ...in a new carbon brush Check the position of the spring on the brush It must be in the middle of the brush The carbon brush is a wearing part and has to be exchanged when worn You will find a pair of carbon brushes enclosed Check the second brush as well When the handpiece becomes warm Should the handpiece become warm or make loud running noises probably the ball bearings in the handpiece front par...

Страница 10: ...10 Exploded Drawing Explosive Drawing for Service Repair Shops ...

Страница 11: ...6234 to which this declaration relates are conform to the following standards or normative documents 2014 30 EU directive EMC 2014 35 EU low voltage directive hadewe GmbH Grambartstraße 10 30165 Hannover Germany Symbols Caution Important note Follow instructions for use protection class II direct current safety fuse alternating current date of manufacture name and address of the manufacturer Dispo...

Страница 12: ...hadewe GmbH Grambartstraße 10 30165 Hannover Germany info hadewe de www hadewe de ...