isolator switch (with at least 3 mm contact spacing) must be used in
order to meet the safety regulations.
•
The appliance is designed for a power supply of 220-240 V~ Using
preinstalled linkages. If your supply is different, contact the authorized
service personnel or qualified electrician.
•
The power cable must be long enough to be connected to the appliance.
•
The fused switch must be easily accessible once the appliance has been
installed.
•
Ensure all connections are adequately tightened.
•
Fix the supply cable in the cable clamp and then close the cover.
•
The terminal box connection is placed on the terminal box.
•
Green/Yellow (Earth) wire to the terminal marked "PE".
•
Brown (Live) wire to the terminal marked "L1".
•
Live Linkages fitted between “L1 -L2” & “L2 – L3”
•
Blue (Neutral) wire to the terminal marked "N1".
•
Neutral linkage fitted between “N1 – N2”.
•
For this connection, a ‘Twin and Earth 6242Y’ type cable should be used.
•
The mains cable must pass through the cable clamp.
•
The mains cable should be routed away from the appliance and in
particular the ventilation slots, the vent outlets and should not be
obstructed when pushed into position between the appliance and the
wall and/or cabinets.
•
Ensure the power supply cord is not trapped under the appliance or that
it becomes damaged when moving the appliance into location.
SHOULD THE MAINS LEAD OF THE APPLIANCE BECOME DAMAGED
OR NEED REPLACING AT ANY TIME, IT SHOULD BE REPLACED BY A
QUALIFIED ELECTRICIAN.
DO NOT DISASSEMBLE THIS APPLIANCE. TOUCHING SOME OF
THE INTERNAL COMPONENTS CAN BE EXTREMELY HAZARDOUS