Sampler Programming Options
6507programming.fm
Section 3
Example 3:
You want to collect 96 samples over a 24-hour period on a 4–20
mA flow proportional basis.
Average Flow Rate = 0.52 mgd (average flow rate over the 24-hour period)
Maximum Flow Rate = 2 mgd
a = 1440 minutes
1.
Calculate
Q
.
2.
Calculate
t
.
3.
Multiply
Q
x
t.
Therefore, the value entered for
INTV = _ _ _ _ CNTS
is 4.
Example 4:
You want to collect 32 samples over an 8-hour period.
Average Flow Rate = 70 gpm (average flow rate over the 8-hour period)
Maximum Flow Rate = 210 gpm
a = 480 minutes
1.
Calculate
Q
.
2.
Calculate
t
.
3.
Multiply
Q
x
t
.
Therefore, the value entered for
INTV = _ _ _ _ CNTS
is 5.
Example 5:
It is desired to collect 30 samples over a 2-day period.
Average Flow Rate = 0.25 cfs (average flow rate over the 48-hour period)
Maximum Flow Rate = 1 cfs
a = 2,880 minutes
1.
Calculate
Q
.
2.
Calculate
t
.
3.
Multiply
Q
x
t
.
Therefore, the value entered for
INTV = _ _ _ _ CNTS
is 24.
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
0.52 mgd
2.0 mgd
-------------------------
0.26 mgd
=
=
=
t
a
n
---
1440 min
96 samples
-------------------------------
15 min/sample
=
=
=
0.26 mgd
15 min/sample
×
3.9
=
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
70 gpm
210 gpm
-----------------------
0.33 gpm
=
=
=
t
a
n
---
480 min
32 samples
-------------------------------
15 min/sample
=
=
=
0.33 mgd
15 min/sample
×
4.95
=
Q
Average Flow Rate
Maximum Flow Rate
------------------------------------------------------
0.25 cfs
1 cfs
---------------------
0.25 cfs
=
=
=
t
a
n
---
2,880 min
30 samples
-------------------------------
96 min/sample
=
=
=
0.25 cfs
96 min/sample
×
24
=
Содержание Sigma 1600
Страница 2: ...Visit http www hach com ...
Страница 12: ...Visit http www hach com ...
Страница 16: ...Page 16 Electrical Connections 6507installation fm Section 2 Figure 4 Sigma 1600 Automatic Sampler Wiring ...
Страница 17: ...Section 2 Page 17 6507installation fm Electrical Connections Figure 5 Control Panel Wiring ...
Страница 22: ...Visit http www hach com ...
Страница 32: ...Visit http www hach com ...
Страница 34: ...Visit http www hach com ...
Страница 36: ...Visit http www hach com ...
Страница 38: ...Visit http www hach com ...
Страница 44: ...Visit http www hach com Figure 14 Dipper Housing ...
Страница 46: ...Visit http www hach com ...
Страница 50: ...Visit http www hach com ...