background image

may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at their expense. The following techniques can be
used to reduce interference problems:

1.

Move the equipment away from the device receiving the interference.

2.

Reposition the receiving antenna for the device receiving the interference.

3.

Try combinations of the above.

Product overview

The Pocket Pro

 conductivity

LR

 tester and conductivity

HR

 tester measure the conductivity

of general water samples. Refer to 

Figure 1

. These tester is waterproof and floats.

Figure 1  Product features

1   

Sensor cap

3   

Keypad

5   

Lanyard attachment

2   

Sensor

4   

Display

6   

Pocket clip

Product components

Make sure that all components have been received. Refer to 

Figure 2

. If any items are

missing or damaged, contact the manufacturer or a sales representative immediately.

4

Содержание Pocket Pro CondLR

Страница 1: ...User Manual DOC022 52 80396 Pocket Pro CondLR CondHR 1...

Страница 2: ...equential damages resulting from any defect or omission in this manual The manufacturer reserves the right to make changes in this manual and the products it describes at any time without notice or ob...

Страница 3: ...plier for instructions on how to return end of life equipment producer supplied electrical accessories and all auxiliary items for proper disposal Certification Canadian Radio Interference Causing Equ...

Страница 4: ...tion the receiving antenna for the device receiving the interference 3 Try combinations of the above Product overview The Pocket Pro conductivityLR tester and conductivityHR tester measure the conduct...

Страница 5: ...ical type and are inserted in the correct orientation Do not mix new and used batteries WA RNING Fire hazard Battery substitution is not permitted Use only alkaline batteries Install the four AAA alka...

Страница 6: ...y power is less than 10 Shows when the lock feature is on When the lock feature is on the parameter value on the display does not change Push to set the lock feature to on or off Shows when the tester...

Страница 7: ...standard CondLR tester One or two auto recognition calibration standards 1 Set the power to on 2 Remove the cap from the sensor 3 Push to go to calibration mode The auto recognition standard s the te...

Страница 8: ...perature compensation factor linear 0 00 to 9 99 per C default 2 00 per C The correction factor may need to be identified experimentally For example the factor for ultrapure water is 4 55 per C and th...

Страница 9: ...rature range of the tester Contact technical support as necessary Note The tester can still be used if a temperature sensor failure has occurred but without automatic temperature compensation Battery...

Страница 10: ...ach com www hach com HACH LANGE GMBH Willst tterstra e 11 D 40549 D sseldorf Germany Tel 49 0 2 11 52 88 320 Fax 49 0 2 11 52 88 210 info hach lange de www hach lange de HACH LANGE S rl 6 route de Com...

Отзывы: