Appendix A
Page 107
8990apdx_quickstart.fm
Quick Start Guides
Sigma 900 MAX Refrigerated Sampler Options Flow Chart
Calibration
Advanced
Options
or
select
Diagnostics
Time /
Date
Data Log
Screen Saver
Mode
(AC power only)
Load Program
Communications
Setup
Flow Totalizer
Alarms
Distributor, Event List, Keypad, LCD, Liquid Sensor, Velocity Analysis, Thermal System
select
or
select
select
Select Inputs
Set Memory
Mode
(Slate or Wrap)
select
Proc. Temp.
Rainfall
pH / ORP
Level / Flow
Cabinet Temp
Channel 1
Channel 2
Channel 3
Ch 4 or DO
Ch 5 or DO Temp
Ch 6 or Cond
Ch 7 or Cond Temp
Velocity
or
select
RS232 Setup
Modem Setup
or
select
select
Set Baud Rate
Enable / Disable
Modem Power
Modify Setup
select
Reset
or
select
View Totals
or
select
Select Scaling (X n)
select
Reset Totalizer (Y/N)
Resettable Total = _____
Non-Resetable Total = _____
select
See
ALARMS
Flowchart -
Select
Logged
or
Not
Logged
Set Logging
Interval
If
Logged
pick
one
4-20 mA
Outputs
Enable
or
Disable
Select
Output
A or B
Select a
Channel to
Assign to Output
A or B
Enter 4 mA Input Value
select
Accept
See
CALIBRATION
Flowchart -
or
Accept
Enter 20 mA Input
Value
or
or
Select Total Flow Units
(af, cf, gal, l or m
3
)
select
or
Arrow
Indicates
Item is Logged
Main Menu
Options
Setup
Status
Display Data
or
or
Select Units
(if applicable)
select
or
Select Program #1 - 5
select
Enable or Disable
select
select
Flow Meter
Setup
Select Flow Units
(GPS, GPM, GPH,
LPS, LPM, LPH, MGD,
AFD, CFS, CFM, CFH,
CFD, CMS, CMM,
CMH, CMD)
select
Select
Level
Units (IN,
FT, M,
CM)
Select Primary
Device (None-Level
Only, Manning, Weir,
Flume, Nozzle, PWR
Equation, Head vs
Flow, Area Velocity)
Select Total
Flow Units
(AF, CF,
GAL, LTR,
M
3
)
or
Select Baud Rate
(1200 or 2400)
Enter Phone #
Select either
Tone or Pulse
dialing
Extended
Power
Mode
Enable/Disable
or
Velocity Setup
select
or
Direction
Units
Cutoffs
Default
Upstream, Downstream, or Always Positive
select
Fps(Feet per Sec), or M/S(Meters per sec.)
select
Enter Cutoff Value Required for Valid Velocity
select
Value Used When Cutoff is Reached
select
Содержание 900 MAX
Страница 1: ...Catalog Number 8990 Sigma 900 MAX Refrigerated Sampler INSTRUMENT MANUAL 07 03 4ed ...
Страница 2: ......
Страница 4: ...Visit http www hach com ...
Страница 16: ...Visit http www hach com ...
Страница 24: ...Visit http www hach com ...
Страница 36: ...Visit http www hach com ...
Страница 38: ...Visit http www hach com ...
Страница 70: ...Visit http www hach com ...
Страница 98: ...Visit http www hach com ...
Страница 114: ...Visit http www hach com ...
Страница 148: ...Visit http www hach com ...
Страница 150: ...Visit http www hach com ...