INSTRUMENT CONDITIONS
SN:0602
V1.0
Monday 30 July 2010
15:50
------------------------------------------------------------------------
pH MEASUREMENT
Resolution.............................................................................0.01
Measurement..........................................................By stability
Criteria.......................................................................... Standard
Type of calibration ....................................Technical buffers
Frequency of calibration..................................... Every 24 h.
mV MEASUREMENT
Resolution...................................................................................1
Measurement..........................................................By stability
Criteria.......................................................................... Standard
Type of calibration ...................................Standard 220 mV
SYSTEM
Codification ............................................................. Automatic
Data send .........................................................................Printer
Type of printer.............................................................Thermal
Type of report .............................................................Reduced
Samples by report........................................................Several
Readjust temperature..........................................................No
------------------------------------------------------------------------
pH CALIBRATION
New cal in 24 h
DATA LOGGER
SYSTEM
pH MEASURE
New cal in 24 h
10-04-2010 17:15
...
Start pH measurement
...by stability
Resolution: 0.01
Meas.: By stability
Display mV: No
Limits: No
Isopotential: pH 7
Measurement condit.
Technical Buffers
DIN 19266 Buffers
User buffers
To a X value
Data Introduction
Theoretical cal.
Cal. frequency
Calibration pH
...
Start calibration
Technical buffers
mV MEASURE
10-04-2010 17:15
10-04-2010 17:15
10-04-2010 17:15
Display data
Reset
DATA LOGGER
Display data
Reset
DATA LOGGER
10-04-2010 17:15
Sample ID
Data output
Type of report
Users
Header
SYSTEM
pH * * * *
21
˚
C
00:30
000001
MEASURING
by stability
Identify sensor
Date / Time
Language
Display contrast
Readjust temp.
Stirring
Temperature units
Instrument condit.
Display data :
Measurement data
Electrode report
Calibration data
DATA LOGGER
Codification:
Automatic
Manual
SYSTEM
Technical Buffers
Use first buffer
Continue...
CALIBRATING pH
Print:
Measurement data
Electrode report
Calibration data
Calibration report.
DATA LOGGER
CALIBRATING
1st buffer
pH 7.15 25
˚
C
Stirring
23%
00:23
4. Operation
4.4. General diagram
This is a general view over the way to access to all possibilities of the instrument:
Example of report
7
ENGLISH
Reprogramation of pH measurements.
See pages 10-11.
pH calibration.
See pages 8 and 9
See page 15.
System.
See page 16.
Note:
The
sign on the
display indicates flashing.
Measurements of mV.
See page 14.