I. PREVENTATIVE MAINTENANCE

  WARNING: RISK OF DEATH, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR 

OTHER PERSONAL INJURY!

 

DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS-
SION OF OWNER AND READING AND UNDERSTANDING PRODUCT 
MANUAL.

DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED 
AREAS.

 WARNING: RISK OF PERSONAL INJURY!

 

EMPLOY BEST HEALTH AND SAFETY LIFTING PRACTICES WHEN REMOV-
ING SHIPPING PLATFORM(S); LEVELING CABINET; REVERSING DOORS; AND 
MOVING APPLIANCE. IF IN DOUBT, ASK FOR HELP.

EMPLOY BEST HEALTH AND SAFETY PERSONAL PROTECTION PRACTICES 
AND ADHERE TO MANUFACTURER’S WARNINGS WHEN USING TOOLS AND 
CLEANING AGENTS.

 

USE CARE WHEN HANDLING OR CLEANING METAL PARTS.

  NOTICE: RISK OF APPLIANCE DAMAGE!

 

MAINTAIN A CLEAN CONDENSER COIL (BOX-SHAPED COMPONENT LO-
CATED BEHIND THE LOWER GRILL) TO PREVENT DAMAGE TO REFRIGERA-
TION PARTS AND POOR PERFORMANCE NOT COVERED UNDER WARRANTY. 
QUALIFIED PROFESSIONAL TO DISCONNECT APPLIANCE FROM ELECTRI-
CAL RECEPTACLE PRIOR TO REMOVING AIR FLOW GRILL FOR MAINTE-
NANCE OR SERVICE.

 

USE ONLY MILD ANTI-BACTERIAL, NON-ABRASIVE ‘DISH SOAP’ DETERGENT 
AND SOFT CLOTH OR BRISTLE BRUSHES FOR CLEANING YOUR APPLIANCE. 
FOR STUBBORN RESIDUE, SUCH AS GREASE BUILD-UP ON CONDENSER 
(HEAT-EXCHANGE) COIL, EMPLOY THE SERVICES OF A QUALIFIED PROFESSIONAL.

KEEP YOUR CONDENSER 

(HEAT EXCHANGE) COIL CLEAN TO AVOID ELECTRICAL/COM-

PONENT OVERHEATING AND POTENTIAL OF FIRE; PREVENT 

DAMAGE TO REFRIGERATION PARTS; AND, MAINTAIN OPTI-

MUM COOLING PERFORMANCE. FAILURE TO DO SO WILL VOID 

WARRANTY.

Free&Clear™ Finless Condenser Coil  

 

Commercial Refrigerators require the grill to be removed for condenser 
(heat-exchange) coil cleaning (Fig I1). All refrigeration devices require 
thorough cleaning of the condenser coil (heat exchange coil located be-
hind the lower grill). Visually inspect the condenser coil for build-up of 
grease, floor wax, dust and lint monthly. At minimum, cleaning should 
be  completed  on  a  monthly  basis.  Use  a  dusting  wand  (Fig  I1)  and  a 
vacuum with soft bristle nozzle, to remove light dust and debris.

FIG. I1

FIG. I1

If the build-up proves to be too difficult to manage, please contact a 
qualified professional. 

-An open box of baking soda placed on a shelf at the rear of the cabi-
net  will  help  prevent  odors.  The  box  should  be  replaced  every  three 
months.

-Maintain clean cooler, inside and out, at all times. 

J. CLEANING PROCEDURES

  WARNING: RISK OF DEATH, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR 

OTHER PERSONAL INJURY!

 

DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS-
SION OF OWNER AND READING AND UNDERSTANDING PRODUCT 
MANUAL.

 

DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED 
AREAS.

 

  WARNING: RISK OF PERSONAL INJURY!

 
 

USE ONLY MILD ANTI-BACTERIAL, NON-ABRASIVE ‘DISH SOAP’ DETERGENT, 
AND SOFT CLOTH (OR BRISTLE BRUSHES WHERE SPECIFIED) FOR CLEANING 
YOUR APPLIANCE. FOR STUBBORN RESIDUE, SUCH AS GREASE BUILD-UP 
ON CONDENSER (HEAT-EXCHANGE) COIL, EMPLOY THE SERVICES OF A 
QUALIFIED PROFESSIONAL.

 

USE CARE WHEN HANDLING OR CLEANING METAL PARTS.

  NOTICE: RISK OF APPLIANCE DAMAGE! AFTER ACCESSING REFRIGERATION 

OR ANY OTHER MECHANICALLY FASTENED AREAS  OF THE APPLIANCE, RE-
FASTEN SECURELY.

1.  Interior Cabinet Cleaning: A mild mixture of anti-bacterial deter-

gent and warm water with a soft cloth may be used. Rinse and dry 
thoroughly. 

2.  Interior Stainless Steel Cleaning: For general cleaning of the stain-

less steel floor please follow instructions in section (i) noted above. 

3.  Evaporator Chamber Cleaning: Refrigeration Cassette® must be re-

moved according to Section G of this manual. A mild mixture of 
anti-bacterial detergent and warm water with a soft cloth, may be 
used to clean the general surfaces within the appliance evaporator 
chamber. Rinse and dry thoroughly. Inspect foam gaskets located 
on cold air side of insulated Cassette® bulkhead for any signs of 
bacterial contamination (decomposition and/or odor) . If contami-
nation is at all prevalent, the foam gaskets must be replaced. Call 
for service.

4.  Cleaning Condensate Drain Tubes: Refrigeration Cassette® must be 

removed according to Section G of this manual. Condensate drain 
tubes run from the evaporator pan to the condensate pan on all 
HABCO® Cold Space Merchandiser® models. 

  NOTICE: RISK OF APPLIANCE DAMAGE! DO NOT PUSH, LEAN-ON OR FORCE 

STAINLESS STEEL TUBE EXTENDING FROM CABINET IN THE CASSETTE® 
REFRIGERATION CHAMBER.  DO NOT FORCE REFRIGERATION CASSETTE® 
WHEN REINSTALLING. SLIDE INTO PLACE GENTLY AND EVENLY, APPLYING 
EQUAL PRESSURE TO EACH SIDE OF CASSETTE®.

i. 

Place a pan beneath the condensate-tray-end of the stain-
less steel tube. Remove debris with a nylon soft bristle, bottle 
brush  soaked  in  anti-bacterial  detergent  and  warm  water. 
Flush with a mild mixture of antibacterial detergent and warm 
water several times to remove debris or residue. Rinse thor-
oughly.

Содержание SE40eHC

Страница 1: ...RUCTION MANUAL Commercial Refrigerators Made In Canada 501 Gordon Baker Road Toronto Ontario Canada M2H 2S6 Tel 416 491 6008 Fax 416 491 6982 Toll Free in Canada 1 800 387 5398 Toll Free in U S A 1 80...

Страница 2: ......

Страница 3: ...n Subject Page INFORMATION AND TABLE OF CONTENTS 2 SAFETY 3 A INSPECTION UNPACKING 4 B LOCATION 4 C ELECTRICAL 4 D START UP 5 E THERMOSTAT LOCATION ADJUSTMENT 5 F LIGHTING 6 G CASSETTE ACCESS REMOVAL...

Страница 4: ...BRUSHES WHERE SPECIFIED FOR CLEANING YOUR APPLIANCE FOR STUBBORN RESIDUE SUCH AS GREASE BUILD UP ON CONDENSER HEAT EXCHANGE COIL EMPLOY THE SERVICES OF A QUALIFIED PROFESSIONAL CABINET MUST BE LEVELE...

Страница 5: ...refrigerator by threading into existing leg leveler hole WHEN ROLLING REFRIGERATOR INTO POSITION ENSURE THE FRONT CASTERS EXTEND OUT WARD FROM THE CABINET FACE iii When in place engage brakes on front...

Страница 6: ...HOUT PERMIS SION OF OWNER AND READING AND UNDERSTANDING PRODUCT MANUAL DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED AREAS NOTICE DIGITAL THERMOSTAT ADJUSTMENT FROM SPECIFIC PARAM ETERS OUTL...

Страница 7: ...EPTACLE IF POWER CORD IS DAMAGED DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS SION OF OWNER AND READING AND UNDERSTANDING PRODUCT MANUAL DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FAST...

Страница 8: ...F IN DOUBT ASK FOR HELP NOTICE HABCO WARRANTS FACTORY DOOR REVERSAL ONLY ANY IS SUES AND SUBSEQUENT SOLUTIONS ARISING FROM FIELD REVERSED DOORS ARE THE RESPONSIBILITY OF THE CUSTOMER DOOR ADJUST MENTS...

Страница 9: ...sition reinstall hinge tensioning bracket onto the square portion of the hinge post at 45 angle from face of cabinet Fig H5 FIG H5 10 Push hinge tensioning bracket into tensioned position flush to fac...

Страница 10: ...tom track 5 Inspect upper horizontal top door track V shaped sealer strip to ensure that it is not binding but freely resting atop inner and outer door frame edges to create a seal Fig 4 6 Test both i...

Страница 11: ...lf at the rear of the cabi net will help prevent odors The box should be replaced every three months Maintain clean cooler inside and out at all times J CLEANING PROCEDURES WARNING RISK OF DEATH FIRE...

Страница 12: ...hinder smooth op eration Use a mild solution of anti bacterial detergent and warm water with a soft damp cloth for cleaning For stubborn residue gently massage with soapy solution and a soft bristle...

Страница 13: ...used to connect power Is the appliance overloaded with product Is there adequate ventilation Is the condenser plugged with grease and or dirt Are the doors closing properly Do the gaskets seal snugly...

Отзывы: