Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Regulating Unit PMR-06
Fax. ++39(0)438.200545
Author:
S.D.T. / KM
SCREEN PAGES MENU
Editon: 12/2005
Page
E-38
Replaces: 05/2005
TABLE
11
-
P
ID FUNCTIONS AND CONSTANTS
PID FUNCTION and CONSTANTS
dP1 10
from
0
to
90
% Set-SP2/3 [1]
0
Proportional Band ( + ) PID
dP2 10
from
0
to
90
% Set-SP2/3 [1]
0
Proportional Band ( - ) PID
BP 3.5
from
0
to
999
Sec [1]
0
Proportional constant
TI 8
from
0
to
999
Sec [1]
0
Integration constant
TD 900
from
0
to
99
Sec [1]
0
Derivative constant
BPPr 180
Sec [1]
Proportional Band as % with respect to
cushion pressure regulation
TIPr 3
Sec [1]
Integration time constant for cushion
pressure regulation.
TDPr 0
Sec [1]
Derivative time constant for cushion
pressure regulation
TRC 2
Sec [1]
PID function recalculation time
PWM 6
Sec [1]
Remaining PWM period
TABLE
12
-
R
EMOTE CONTROL PARAMETERS
REMOTE CONTROL PARAMETERS
ADD 1
from
0
to
32
Numbers
0
Regulating unit address
BAUDS 9600
from 2400 to be
set
Number - standard
0
Baud Rate
Regulating Unit PMR-06