8
For
Classic Haas Control
:
• Set Setting 7, Parameter Lock, to OFF.
• Set Parameter 710, Tool Changer Type, to 4.
• Change Setting 113, Tool Change Method, to AUTO.
• Record the parameter values on the identification plate [3].
• Put these values into Parameter 128, and Parameter 212.
For
Next Generation Control
:
• Login to the
• Download the option configuration patch files.
• Load the option configuration patch file to the control. Refer to the
CONFIGURATION FILE - DOWNLOAD/LOAD
procedure.
• Insert the Service USB Key and go into Service Mode.
• Press
[DIAGNOSTIC]
button.
• Navigate to Parameters -> Factory tab
Change the following parameters:
• 9.019 [390:18] TT_AXIS INVIS AXIS = FALSE
• 9.078 [415] TT_AXIS TOOL CHANGE OFFSET = 0.000
• 9.140 [409] TT_AXIS GRID OFFSET = 0.000
• Press the
[Position]
button and then press
[ALTER]
button.
• Select the TT axis.
• Zero Return the TT axis, ignore any alarms.
• In parameter mode, set the grid offset by typing TT + [F4.]
• Zero Return the TT axis.
• Jog the turret to tool #1 by pressing
[Turret FWD]
or
[Turret REV]
(which ever is quickest) in
MDI
mode
• Press
[E-stop].
Set the Tool Change Offset.
• In Parameter Mode press TT +
[F2].
• Change parameter 9.019 [43:18] TT_AXIS INVIS to True.
• Zero Return the TT axis.
TL-1/2 - ATT-4/8 Turret - Installation and Alignment - AD0304