background image

T

echnical

data

1

1. Technical data

Pelletto III 419.08

Pelletto III 434.08

Heat output range:

2,4 – 8,3 kW

2,4 – 8,3 kW

Nominal heat output:

8,0 kW

8,0 kW

Height:

988 mm

1180 mm

Width:

529/531 mm

531/533 mm

Depth:

508 mm

498 mm

Weight:

96/143/115 kg

106/137 kg

Diameter of flue elbow:

80 mm

80 mm

Flue gas temperature:

206 °C

206 °C

Testing transport pressure at nominal output:

11 Pa

11 Pa

Testing transport pressure at partial output:

5 Pa

5 Pa

Flue gas flow rate in g/s

5,6 g/s

5,6 g/s

CO level in flue gas (%) (min./max.)

0,001/0,023 %

0,001/0,023 %

Efficiency:

90/95 %

90/95 %

CO level in flue gas:

15 mg/Nm³

15 mg/Nm³

NOx level in flue gas:

143/- mg/Nm³

143/- mg/Nm³

OGC level in flue gas:

<5 mg/Nm³

<5 mg/Nm³

Proportion of dust in flue gas:

9/- mg/Nm³

9/- mg/Nm³

Contents of storage container (pellet tank):

about 17 kg

about 32 kg

Duration of burn with one charge (min./max.):

about 10 h/30 h

about 20 h/60 h

Permitted fuel: Low-dust wood pellets

diameter: 6 mm

diameter: 6 mm

to Ö-Norm M 7135, DIN plus, EN plus-A1

length: max. 30 mm

length: max. 30 mm

Room heating capacity to Ö-Norm M 7521:

max. 230 m³

max. 230 m³

Room heating capacity to DIN 18893, constant heating:

250m³/145m³/98m³

250m³/145m³/98m³

Room heating capacity to DIN 18893, timed heating:

165m³/95m³/65m³

165m³/95m³/65m³

Electricity supply:

230 V (50 Hz)

230 V (50 Hz)

Electricity supply input:

in normal operation:

max. 50 W

max. 50 W

Electric ignition (for max. 15 minutes on ignition):

max. 380 W

max. 380 W

Electronics fuses: (F3)

T 0,315 A, 250 V

T 0,315 A, 250 V

Fuses for the ignition, screw conveyor motor, induced
draught, (F1)

T 3,12 A, 250 V

T 3,12 A, 250 V

Safety distances

Minimal distances from flammable materials:

side:

15 cm

rear:

10 cm

front (radiation area):

80 cm

Содержание HSP 6 Pelletto III 419.08

Страница 1: ...lletofen DE Fiche technique Po le pellets FR Scheda tecnica Stufe pellet IT Equipment sheet Pellet stove GB Tehni ki list Kotel na pelete HR Tehni ni list Kotel na pelete SLO 0541908101400d Technische...

Страница 2: ...heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the ope...

Страница 3: ...ction Error F040 4 3 4 Cleaning the combustion pot weekly 4 4 Maintenance work 6 4 1 Cleaning the pellet container annual maintenance 6 4 2 Cleaning the flue gas passes long time 7 5 Replacement parts...

Страница 4: ......

Страница 5: ...Contents of storage container pellet tank about 17 kg about 32 kg Duration of burn with one charge min max about 10 h 30 h about 20 h 60 h Permitted fuel Low dust wood pellets diameter 6 mm diameter 6...

Страница 6: ...Dimensions 2 2 Dimensions 2 1 Dimensions Pelletto III 419 08 2 2 Dimensions Pelletto III 419 08 C...

Страница 7: ...Dimensions 3 2 3 Dimensions Pelletto III 434 08 2 4 Dimensions Pelletto III 434 08 C...

Страница 8: ...the OFF operating mode 3 3 Clean combustion chamber function instruction Error F040 The whole combustion space must be cleaned after 30 hours operation at the latest or once a week The requirement to...

Страница 9: ...ing in the pellet tank might possibly result This will destroy your device and is not covered in your guarantee WARNING Cleaning the combustion pot may only be done with a cooled down stove in OFF ope...

Страница 10: ...or 3 times WARNING Devices that are not maintained in accordance with our specifications must not be operated Failure to observe this point will invalidate all guarantee claims 4 1 Cleaning the pellet...

Страница 11: ...ellets at the latest it is recommendable to check clean the conduits of combustion products the induced draught fan and the smoke flues For cleaning employ a brush or an ash exhauster Please perform t...

Страница 12: ...e cleaning as pr the Fig 3 Figure 3 Removing the side wall CAUTION After completion of the cleaning make sure that when putting back the covers the seals are seated in the right positions It is essent...

Страница 13: ...Replacement parts list 9 5 Replacement parts list 5 1 Replacement parts list Pelletto III 419 08 434 08 without trim parts...

Страница 14: ...10 10 Door hinge complete grey 1 piece 0551908015410 11 Complete control unit 1 piece 0541908005569 12 Backup battery CR 2032 1 piece 13a Stand front 2 piece 0089501090005 13b Stand back 2 piece 05519...

Страница 15: ...34 Screw UN5950 M5x10 4 piece 5 2 Detail A1 Pos Description Piece No PR Detail A1 A1 1 Screwing door 1 piece 0541908305001 A1 2 Door hinge anthracite Set 1 piece 0541908005340 A1 2 Door hinge grey Set...

Страница 16: ...ment parts list Pelletto III 419 08 Pos Description Piece No PR Replacement parts list Pelletto III 419 08 39 Side wall right grey 1 piece 0541908016150 39 Side wall right anthracite 1 piece 054190800...

Страница 17: ...eplacement parts list Pelletto III 419 08 C 43 Side wall right anthracite 1 piece 0541908006140 44 Side part C ceramic ahorn right 1 piece 0541908016185 45 Front plate anthracite 1 piece 0541908006120...

Страница 18: ...acement parts list Pelletto III 434 08 49 Side wall right grey 1 piece 0543408006140 49 Side wall right white 1 piece 0543408116140 50 Front plate anthracite 1 piece 0543408006120 51 Side wall left gr...

Страница 19: ...0543408716140 54 Side part C ceramic ahorn right 1 piece 0543408716185 54 Side part C ceramic coffee bean right 1 piece 0543208716185 55 Front plate anthracite 1 piece 0541908006120 56 Side wall left...

Страница 20: ...Circuit diagram 16 6 Circuit diagram Circuit diagram IO 33 3...

Страница 21: ...onveyor motor 7 Induced draught 8 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48...

Отзывы: