GB
1
1. Technical data
HSP 4.0–F2 456.08
Nominal
output
Partial output
50%
Partial output
30%
Heat output range:
8,5 kW
3,7 kW
2,6 kW
Nominal heat output:
8,5 kW
Test conditions defined by norm:
EN 14785
Height:
1206 mm
Width:
954 mm
Depth:
380 mm
Weight:
232 kg
Diameter of flue elbow:
80 mm
Flue gas temperature:
132 °C
78 °C
65 °C
Testing transport pressure:
12 Pa
6 Pa
6 Pa
Flue gas flow rate in g/s:
5,5 g/s
3,8 g/s
3,2 g/s
CO level in flue gas (%) (min./max.)
0,001 %
0,016 %
0,021 %
Efficiency:
94 %
95,3 %
96 %
CO level in flue gas:
16 mg/Nm³
199 mg/Nm³
268 mg/Nm³
NOx level in flue gas:
80 mg/Nm³
75 mg/Nm³
55 mg/Nm³
OGC level in flue gas:
3 mg/Nm³
8 mg/Nm³
12 mg/Nm³
Proportion of dust in flue gas:
4 mg/Nm³
10 mg/Nm³
9 mg/Nm³
Contents of storage container (pellet tank):
about 40 kg
Duration of burn with one charge (min./max.):
about 21 h
about 44 h
about 44 h
Permitted fuel: Low-dust wood pellets
diameter: 6 mm
to Ö-Norm M 7135, DIN plus, EN plus-A1
length: max. 30 mm
Room heating capacity to Ö-Norm M 7521:
max. 230 m³
Electricity supply:
230 V (50 Hz)
Electricity supply input:
in normal operation:
18,9 W
Electric ignition (for max. 15 minutes on ignition):
max. 380 W
Fuses for the ignition, screw conveyor motor, induced
draught, (F1)
T 3,15 A, 250 V
Safety distances
Minimal distances from flammable materials:
side left:
2 cm
side right:
8 cm
rear:
5 cm
front (radiation area):
60 cm