background image

  13 

 

8.1. 

Cleaning the surface 

Dirt  on  the  upper  surface  of  the  stove  may  be  cleaned 
off  with  a  damp  cloth  or  if  necessary  with  mild  soapy 
water. You are advised against using corrosive cleaning 
agents  and  solvents  since  these  might  damage  the 
surfaces. 
 

8.2. 

Cleaning the glass panel 

 
To  clean  the  viewing  panel,  you  must  first  open  the 
stove door. Dirt on the glass panel can be removed with 
a  glass  cleaner  or  with  a  damp  sponge  on  which  you 
have  sprinkled  some  of  the  wood  ash  present. 
(Environmentally friendly). 
Cleaning  the  glass  panel  may  only  be  done  with  a 
cooled down stove in the OFF operating mode. 

8.3. 

Clean combustion chamber” function 
instruction 

Die  The  display  on  the  operator  console  starts  flashing.  
(The  backlighting  switches  on  and  off  and  the  “Clean 
combustion chamber” instruction appears). 
The  instruction  to  clean  the  combustion  chamber  refers 
not  just  to  the  cleaning  of  the  burner  but  also  to  the 
cleaning  of  the  entire  combustion  chamber  with  an  ash 
vacuum cleaner. 
The  process  of  the  “Clean  combustion  chamber” 
function looks like this: 
The entire combustion chamber is to be cleaned with an 
ash  vacuum  cleaner  at  intervals  of  no  longer  than  30 
operating hours. 
The  process  of 

the  “Clean  combustion  chamber” 

function looks like this: 
The entire combustion chamber is to be cleaned with an 
ash  vacuum  cleaner  at  intervals  of  no  longer  than  30 
operating hours. 
However,  this  instruction  to  clean  the  combustion 
chamber  (display  flashing)  does  not  trigger  an  error 
message during Heating mode. But after the display has 
started flashing, if the stove switches  
back  to  “Standby”  mode,  the  stove  can  no  longer  be 
automatically  ignited  before  the  combustion  chamber 
has been cleaned. 
To  clean  the  combustion  chamber,  the  stove  has  to  be 
switched to “Off” operating status. 
If  the  combustion  chamber  is  now  cleaned,  then  the 
“Clean  combustion  chamber”  error  message  will 
thereafter  be  cleared  automatically.  A  precondition  for 
the automatic clearance of this error message is that the 
combustion  chamber  door  is  open  for  longer  than  60 
seconds  in  “Off”  operating  status.  This  time  is  required 
for  cleaning  the  combustion  chamber  including  the 
burner thoroughly with an ash vacuum cleaner. 
If  the  door  is  open  longer  than  60  seconds 

in  “Off” 

operating  status

,  then  the  operating  hours  counter, 

which  is  responsible  for  the  “Clean  combustion 
chamber” instruction, is automatically reset to zero. 
This reset of the operating hours counter occurs even if 
the  cleaning  of  the  combustion  chamber  is  performed 
before the 30 operating hours have run provided that the 
stove is in “Off” operating status and the door is open for 
longer than 60 seconds during cleaning.  

8.4. 

Cleaning the combustion pot -weekly 

During  operation,  deposits  may  form  in  the  combustion 
pot.  How  quickly  the  combustion  pot  becomes  dirty 
depends  solely  on  fuel  quality.  The  deposits  or 
encrustations must be removed from time to time

Cleaning the combustion pot may only be done with a 
cooled down stove in 

“OFF” operating mode. Otherwise 

there is a risk of burns! 

To  this  end  the  combustion  pot  must  be  removed  from 
the stove. Once the combustion pot has been removed, 
any  residual  ash  that  is  in  the  stove  underneath  the 
combustion pot must also be removed.  
After cleaning, the combustion pot is to be put back into 
the  right  position  in  the  burner  seat.  Check  the  correct 
seating of the combustion pot again so as to avoid poor 
seals. 

 
 
 
 
 
 
 
 
 
 
 

Figure 5:  Burner dirty 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 6:  Burner clean

 

 

The  cleaning  intervals  for  the  combustion  pot  and  the 
glass  panel  depend  directly  on  the  quality  of  the  wood 
pellets  (high  ash  content)  and  may  vary  between  a  few 
hours of combustion and several days. 
 
 
 

 

Содержание HSP 2.17

Страница 1: ...e cold combustion pot it must be cleaned See operating instructions If this is not done there will be more and more clinker Then the device will no longer be able to ignite properly Pellets may pile up in the combustion pot In extreme cases this can reach all the way back to the pellet chute Backfire in the pellet container and smouldering in the pellet tank might possibly result This will destroy...

Страница 2: ...ey lock child safe 11 7 Operating the pellet stove 11 7 1 Fuel 11 7 2 Commissioning your pellet stove 12 8 Cleaning and maintenance work 12 8 1 Cleaning the surface 13 8 2 Cleaning the glass panel 13 8 3 Clean combustion chamber function instruction 13 8 4 Cleaning the combustion pot weekly 13 8 5 Cleaning the pellet container annual maintenance 14 8 6 Cleaning the flue gas passes annual maintenan...

Страница 3: ... room enters the stove at the bottom of the cladding is heated and flows out again at the top in the area of the slats The proportion of radiant heat is given off by radiation in the area of the viewing window of the combustion chamber door and from the stove s metal surfaces 2 General instructions safety instructions Before commissioning the pellet stove read the entire installation and operating...

Страница 4: ...cleaning staff should be informed and instructed regarding the possible unexpected heating up of the stove Placing non heat resistant objects on or near the heating device even when it is cold since it can ignite again by itself is forbidden Do not lay any laundry on the stove to dry Clotheshorses for drying clothes and the like must be positioned at sufficient distance from the heating device fir...

Страница 5: ...ecause of the way that the pellet stove works with an induced draught fan all fume outlet pipes as far as the intake to the fireplace must be gas tight It is also essential to ensure that the flue tube does not stick out into the open cross section of the chimney The use of wall lagging is recommended for the insertion into the chimney See Figure 3 With longer flue gas pipework horizontal sections...

Страница 6: ...ded into 20 zones is ended after reaching a precisely defined temperature on the flame temperature sensor and the control unit switches to Heating Mode operating status The duration of the Ignition phase may vary If during these time no flame is formed or the required temperature is not reached at the flame temperature sensor flue gas a safety shutdown is initiated Here the rotation speed of the i...

Страница 7: ...is in a waiting position Before the stove can switch back from Standby operating status to the Ignition phase operating status two ignition conditions must be fulfilled 1 The room temperature must be at least 1 0ºC below the set target room temperature 2 The flue gas temperature measured with the thermosensor must be lower than 70 C It is only when both these ignition conditions have been fulfille...

Страница 8: ...ere it was before the power cut Long power cut duration of the power cut longer than 30 seconds Once the electricity supply is restored the stove switches to Safety shutdown operating status A small amount of flue gas may escape during a power cut 6 Description of operator console keys 6 1 Operator console As can be seen in the figure the display is divided into five areas 6 2 Description of the s...

Страница 9: ...n to switch the stove in operation Now the boot process begins with the launch zone 1 Off Menu Start zone 1 08 13 26 C 23 C 6 3 3 Setting target room temperature Procedure By pressing the middle button and you adjust the room temperature By pressing the OK button the set value is stored OK OFF 08 15 28 C 23 C 6 4 Main menu By pressing the right button the standard screen will appear This menu is a...

Страница 10: ...e 4 With older stoves a higher value should be set over 3 so as to avoid excess condensation in the fireplace Procedure In the main menu place the cursor on Heating profile Press the right OK key Adjust the value with the two middle keys Then press the right OK key If you would like to quit this menu screen without saving press the left Back key 6 4 4 Desription ECO Mode OK No Yes Main menu ECO Mo...

Страница 11: ...onds until Key lock activated is no longer shown on the display 7 Operating the pellet stove The pellet stove may only be heated by adults Make sure that children are never left alone with the pellet stove Do not leave the pellet stove unsupervised for a long period The pellet stove may only be used in accordance with these operating instructions Please observe the safety instructions set out in S...

Страница 12: ... move cursor to Operating mode press the right key Select select the desired operating mode with the cursor press the right key Save Tip Only when commissioning place about 30 pellets in the burner This will speed up the ignition process General If the ignition phase could not be successfully run i e no flame generation or the required temperature could not be reached at the flue gas thermosensor ...

Страница 13: ...mber the stove has to be switched to Off operating status If the combustion chamber is now cleaned then the Clean combustion chamber error message will thereafter be cleared automatically A precondition for the automatic clearance of this error message is that the combustion chamber door is open for longer than 60 seconds in Off operating status This time is required for cleaning the combustion ch...

Страница 14: ...tive grille 1 Tank cover 2 8 6 Cleaning the flue gas passes annual maintenance First pull the stove away from the wall so as to create enough room to work at the back To clean the flue gas passes proceed as follows Disconnect the flue baffle 1 from the guide by lifting it Draw the right cladding 2 down out of the guide and place it down in the ash space Then the flue baffle can be removed and the ...

Страница 15: ...15 2x 2x 3B 1 2 3A 3B 3A 3B Figure 8b Tilt out the front part ...

Страница 16: ...ition again It is essential to replace defective seals Make sure of the electrical connections on the fan motor and their correct positions Figure 9 Induced draught fan 1 Screw 2 Blower motor 3 Seal 9 Description of the components 9 1 Storage container pellet tank 17 kg of wood pellets can be stored in the storage container This quantity permits constant operation for up to 30 hours 9 2 Screw conv...

Страница 17: ... average ignition glow time is depending on pellet quality Figure 12 Electrical components 1 Flame temperature sensor 2 Overheat cutout 3 Bottom temperature sensor 4 Ignition 5 Screw conveyor motor 6 Control unit 7 Backup battery Figure 13 Stainless steel ignition 9 5 Control unit The microprocessor control unit ensures safe automatic operation of the pellet stove The control unit controls the int...

Страница 18: ...e and hence the basis of the air volume required for the combustion of the energy level located in the grate Here the ACTUAL flame temperature is compared with the TARGET in combination with the processor regulated control unit and the appropriate combustion air volume required for the combustion of the energy level in the grate is supplied by means of the induced draught fan 9 9 Flue gas thermose...

Страница 19: ...mm The flue tube must be connected to the fireplace in accordance with official regulations For questions in connection with this please contact your local chimneysweep Because of the way the pellet stove works with a combustion air fan high pressure is generated at the flue gas outlet and possibly in the fireplace This means that the flue gas pipes must be designed to be gas tight as far as their...

Страница 20: ...kg Duration of burn with one charge min max about 10 hrs 30 hrs Permitted fuel Low dust wood pellets to Ö Norm Eco standard M 7135 DIN 51731 EN 14961 2 Diameter 6 mm Length max 30 mm Room heating capacity to Ö Norm M 7521 max 230 m 3 Room heating cap y to DIN 18893 constant heating 250m 3 145m 3 98m 3 Room heating cap y to DIN 18893 timed heating 165m 3 95m 3 65m 3 Electricity supply 230 V 50 Hz E...

Страница 21: ...ction has initiated a safety shutdown Dirty heat exchanger Correction Set the heating profile as description Room temperature sensor is on the floor or on the wall hang the sensor free cleaning the flue gas passes Contact the service engineer Error number 5 Cause Flue gas temperature is starting to fall rapidly despite maximum heat output for a long period The following circumstances might lead to...

Страница 22: ... not running at the correct rotation speed The following circumstances might lead to this Induced draught fan defective Connection cable from the rotation speed sensor Hallsensor is broken or poor contact in the connector on this connection cable Electricity supply to the fan motor interrupted Correction Contact the service engineer Error number 17 Cause The connection between the central unit and...

Страница 23: ...stances might lead to this Too much fuel is being supplied to the burner Flue gas temperature sensor defective Correction Contact the service engineer Error number 23 Cause Flame temperature sensor defective or not connected Correction Contact the service engineer Error number 24 Cause Bottom flame temperature sensor defective or not connected Correction Contact the service engineer Error number 2...

Страница 24: ...ctive Replace fuse F3 in the control unit T0 315 A No display showing 1 Loose or defective connection cable between operator console and control unit Check plugs and sockets otherwise call in the service engineer Fire burns with a tall yellow flame wood pellets piling up in the combustion pot and or the viewing panel is excessively sooty 1 The combustion air supply to the combustion pot is blocked...

Страница 25: ...ner Flue gas escaping 1 Power cut Ventilate room 2 Flue tubes or chimney fireplace very dirty Clean flue tube or chimney fireplace 12 Type plate Symbol HAAS SOHN OFENTECHNIK GMBH Urstein Nord 67 A 5412 Puch Pellet Kaminofen Typenbezeichnung 713 07 Variante HSP 2 17 Wärmeleistungsbereich 1 8 8 2 kW Nennwärmeleistung 8 0 kW Zugelassener Brennstoff Holzpellets Ø 6mm DINplus ÖNorm M 7135 ENplus A1 Prü...

Страница 26: ...gures 21 Replacement parts HSP 2 17 Figures 22 Replacement parts HSP 2 17 32 31 20 15 16 35 10 12 22 38 39 21 32 31 25 36 37 1 8 9 2 41 43 5a 6a 6b 4b 11 26 24 34 23 33 30 28 29 27 23 34 47 4a 4b 46 45 44 43 ...

Страница 27: ...20 Draught baffle plate 21 0571207005701 Allen key 6 mm 43 9001700060005 Stand 22 0561008009641 Mains cable 23 0089500990000 Cable screw conveyor motor with capacitor Ignition 350 W 25 0561008005202 OC 24 0571207005840 Induced draught fan 26 0571207005820 Screw conveyor motor 27 0089500880005 Screw conveyor 28 0571207005030 Lower screw conveyor bearing 30 0089000340008 Motor plate 29 0571207007080...

Страница 28: ...28 14 Circuit diagram ...

Страница 29: ... 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48 50 Flue gas fan rotation speed F1 Fuse T 3 15A ignition induced draught fan screw conveyor motor F2 Fuse T 3 15A reserve F3 Fuse T 0 315A operator console ...

Страница 30: ...draught incorrectly carried out repair work or other in particular subsequent changes to the heating appliance or flue gas pipework stove pipe and chimney use of unsuitable fuels incorrect operation overloading the devices see the manufacturer s operating instructions wear on the parts made of iron or fire clay directly exposed to the flames in so far as they are not covered by the guarantee 1a in...

Страница 31: ...tion stoves for wood and coal Slow combustion stoves and auxiliary ranges for wood coal and oil Fireplace inserts for wood Accessories for stoves and fireplaces Accessories for central oil supply HAAS SOHN Sales in Germany OFENTECHNIK GMBH HAAS SOHN Ofentechnik GmbH Urstein Nord 67 Zur Dornheck 8 A 5412 Puch D 35764 Sinn Fleisbach Email office haassohn com Email info haassohn com http www haassohn...

Отзывы: