background image

4-2 

display

 commands individually. However, you can use the 

display

 

diagnostic-information

 command in any view to display or save the operational statistics of 

multiple feature modules of the device. This command displays the output from the 

display 

clock

display version

display device

, and 

display current-configuration

 

commands. 

 

Save the operational statistics for each feature module of the device: 

<H3C> display diagnostic-information 

Save or display diagnostic information (Y=save, N=display)? [Y/N]:y 

Please input the file name(*.tar.gz)[flash:/diag_WX1804H_20170101-142944.tar.gz] 

Diagnostic information is outputting to flash:/diag_WX1804H_20170101-142944.tar. 

gz. 

Please wait... 

Save successfully. 

To view the contents of the 

XXXX

.tar.gz

 

file, perform the following steps: 

a. 

Execute the 

tar extract

 command to extract the 

XXXX

.gz file from the

 XXXX

.tar.gz

 

file. 

b. 

Execute the 

gunzip 

command to decompress the 

XXXX

.gz file to 

XXXX 

file. 

c. 

Execute the 

more 

command to view the 

XXXX 

file. 

 

Display the operational statistics for each feature module of the device. (Details not shown.) 

<H3C> display diagnostic-information 

Save or display diagnostic information (Y=save, N=display)? [Y/N]:n 

=============================================== 

  ===============display clock=============== 

00:04:29 UTC Mon 01/01/2018 

================================================= 

  ===============display version=============== 

H3C Comware Software, Version 7.1.064, Release 5204P01 

Copyright (c) 2004-2020 New H3C Tech. Co., Ltd. All rights reserved. 

H3C WX1804H-PWR uptime is 0 weeks, 0 days, 0 hours, 4 minutes 

Last reboot reason : Watchdog reboot 

 

Boot image: flash:/boot.bin 

Boot image version: 7.1.064, Release 5204P01 

  Compiled Feb 22 2017 16:00:00 

System image: flash:/system.bin 

System image version: 7.1.064, Release 5204P01 

  Compiled Feb 22 2017 16:00:00 

 

with 1 800MHz Processor 

1024M bytes DDR3 

1024M bytes NandFlash Memory 

 

Hardware Version is Ver.A 

Basic Bootrom Version is 0.22 

Extend Bootrom Version is 0.22 

[Subslot 0]WX1804H-PWR Hardware Version is Ver.A 

 

================================================ 

Содержание WX1800H series

Страница 1: ...H3C WX1800H Series Access Controllers Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W102 20200228...

Страница 2: ...respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be acc...

Страница 3: ...ds or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...l safety recommendations 1 1 Electricity safety 1 2 Laser safety 1 2 Examining the installation site 1 2 Temperature and humidity 1 2 Cleanliness 1 3 Cooling 1 3 ESD prevention 1 3 EMI 1 4 Lightning p...

Страница 7: ...recommendations Make sure the installation site is flat vibration free and away from electromagnetic interferences Make sure ESD and anti slip measures are in place Keep the chassis and installation...

Страница 8: ...ector and a dust plug into any open fiber port or transceiver module port to protect them from contamination and ESD damage Examining the installation site The device can only be used indoors For the...

Страница 9: ...to eliminate corrosion and premature aging of components as shown in Table1 3 Table1 3 Harmful gas limits in the equipment room Gas Max mg m3 SO2 0 2 H2S 0 006 NH3 0 05 Cl2 0 01 NO2 0 04 Cooling The...

Страница 10: ...Secure the wrist strap lock and the alligator clip lock together 4 Attach the alligator clip to the rack 5 Make sure the rack is reliably grounded Figure1 2 Attaching an ESD wrist strap WX1840H EMI Al...

Страница 11: ...bly grounded Install a surge protected power strip at the power input end Installation accessories Figure1 3 Installation accessories Installation accessory WX1804H PWR WX1810H PWR WX1820H WX1840H Cag...

Страница 12: ...R WX1820H WX1840H Bail latch N A N A N A 1 Front mounting bracket N A N A N A 2 Front mounting bracket N A 2 N A N A Installation tools No installation tools are provided with the device Prepare them...

Страница 13: ...rotection ground of the device is away from the grounding facility of power equipment or lightning protection grounding facility The device is far away from radio transmitting stations radar stations...

Страница 14: ...e 2 5 Optional Installing network port lightning protectors 2 8 Optional Installing a surge protected power strip 2 9 Connecting interface cables 2 9 Connecting the console cable and setting terminal...

Страница 15: ...open the chassis contact H3C for permission Otherwise H3C shall not be liable for any consequence Installation prerequisites You have read Preparing for installation carefully All requirements in Prep...

Страница 16: ...art for the WX1810H PWR WX1840H access controller Mounting the device on a workbench CAUTION To avoid damaging the device and affecting heat dissipation do not place heavy objects on the device Make s...

Страница 17: ...d firmly on the workbench Figure2 3 Mounting the device on a workbench Mounting the device in a 19 inch rack IMPORTANT As a best practice reserve a clearance of 1U 44 45 mm 1 75 in between adjacent de...

Страница 18: ...ets to the device 4 Supporting the bottom of the device with one hand and holding the front of the device with the other put the device in the rack Use M6 rack screws and cage nuts to attach the mount...

Страница 19: ...g cable to a length as required by the connection distance 2 Use a wire stripper to strip 5 mm 0 20 in of insulation off the end of the grounding cable 3 Slide the heat shrink tubing onto the cable an...

Страница 20: ...e rack CAUTION To ground the device by using a grounding point on the rack make sure the rack is reliably grounded The WX1810H PWR and WX1840H access controllers support grounding by using a grounding...

Страница 21: ...onductor buried in the earth The following uses the WX1840H access controller as an example If earth is available at the installation site hammer a 0 5 m 1 64 ft or longer angle iron or steel tube int...

Страница 22: ...WX1800H series access controllers The following procedure uses the WX1840H access controller as an example To install a network port lightning protector for a network port 1 Use a double faced adhesiv...

Страница 23: ...with the device Purchase one yourself if required To use a surge protected power strip first connect the AC power line routed from outdoors to the strip and then connect the power cord from the devic...

Страница 24: ...em from contamination and ESD damage Never bend an optical fiber excessively The bend radius of an optical fiber must be not less than 100 mm 3 94 in Keep the fiber end clean Make sure the Tx and Rx p...

Страница 25: ...WR WX1820H access controller If you use the local power source for the WX1804H PWR WX1820H access controller use a power adapter to connect the device to the power source To connect the power adapter...

Страница 26: ...e Appendix A Chassis views and technical specifications Figure2 14 Connecting the AC power cord for the WX1810H PWR access controller Verifying the installation Verify the following items before you p...

Страница 27: ...iled Date Mar 10 2018 CPU Type 1000MHz Multi core Processor Memory Type DDR3 SDRAM Memory Size 1024MB Memory Speed 1333MHz BootWare Size 768KB Flash Size 1024MB CPLD Version 002 PCB Version Ver A Boot...

Страница 28: ...2 14 3 Press Enter at the prompt and you can configure the device when the prompt H3C appears NOTE The CPLD version is automatically upgraded during the start up process...

Страница 29: ...s 3 Troubleshooting 3 1 Power failure 3 1 Symptom 3 1 Solution 3 1 No display or garbled display on the configuration terminal 3 1 Symptom 3 1 Solution 3 1 Software loading failure 3 2 Symptom 3 2 Sol...

Страница 30: ...nfiguration terminal Symptom The configuration terminal does not have display or have a garbled display when the device is powered on Solution To resolve the issue 1 Verify that the power system is op...

Страница 31: ...on the HyperTerminal to check for errors If an error exists correct the error For example check for the following errors that might occur You used XMODEM to load software and set a baud rate other tha...

Страница 32: ...1 Displaying operational statistics for the device 4 1 Displaying information about the device 4 3 Displaying the electronic label data for the device 4 3 Displaying the CPU usage of the device 4 4 Di...

Страница 33: ...e Version 7 1 064 Release 5204P01 Copyright c 2004 2020 New H3C Tech Co Ltd All rights reserved H3C WX1804H PWR uptime is 0 weeks 0 days 0 hours 4 minutes Last reboot reason Watchdog reboot Boot image...

Страница 34: ...le from the XXXX tar gz file b Execute the gunzip command to decompress the XXXX gz file to XXXX file c Execute the more command to view the XXXX file Display the operational statistics for each featu...

Страница 35: ...ating correctly Max Ports Maximum number of ports supported Displaying the electronic label data for the device An electronic label is a profile of a device It contains the permanent configuration inc...

Страница 36: ...es after the device boots the device calculates and records the average CPU usage at an interval of 5 minutes Displaying the memory usage of the device Use the display memory command to display the me...

Страница 37: ...and Schedule a reboot to occur at a specific time or date or after a delay by using the schedule reboot command Power off and power on the device This method cuts off the power of the device forcibly...

Страница 38: ...le a reboot Schedule a reboot to occur at a specific time or date schedule reboot at time date Schedule a reboot to occur after a delay schedule reboot delay time Use either command By default no rebo...

Страница 39: ...ssis views and technical specifications 5 1 Chassis views 5 1 WX1804H PWR 5 1 WX1810H PWR 5 1 WX1820H 5 2 WX1840H 5 3 Interface numbering 5 3 WX1804H PWR 5 3 WX1810H PWR 5 3 WX1820H 5 4 WX1840H 5 4 Te...

Страница 40: ...per port WAN 4 100 1000BASE T PoE autosensing Ethernet copper ports LAN1 to LAN4 5 USB port 6 Console port CONSOLE 7 Reset button RESET Figure5 2 Rear panel WX1810H PWR Figure5 3 Front panel 1 100 100...

Страница 41: ...eptacle WX1820H Figure5 5 Front panel 1 Power receptacle 2 100 1000BASE T autosensing Ethernet copper ports LAN1 to LAN4 and WAN 3 Console port CONSOLE 4 SD card slot 5 USB port 6 Reset button RESET F...

Страница 42: ...ace number GigabitEthernet 1 0 1 100 1000BASE T PoE autosensing Ethernet copper ports LAN1 through LAN4 are represented by interface numbers GigabitEthernet 1 0 2 through GigabitEthernet 1 0 5 respect...

Страница 43: ...0 7 and GigabitEthernet 1 0 8 respectively Technical specifications Table5 1 Technical specifications Item WX1804H PWR WX1810H PWR WX1820H WX1840H Console port One 9600 bps default to 115200 bps One 9...

Страница 44: ...port 4 10 N A N A Max output capacity per PoE port 30 W 30 W N A N A Max PoE output capacity 70 W The system allows two PoE ports to supply the max output concurrently 196 W The system allows six PoE...

Страница 45: ...i Contents 6 Appendix B LEDs 6 1 WX1804H PWR 6 1 WX1810H PWR 6 1 WX1820H 6 2 WX1840H 6 2 LED description 6 2...

Страница 46: ...LEDs for the 100 1000BASE T PoE autosensing Ethernet copper ports 3 System status LED SYS 4 PoE status LED PoE WX1810H PWR Figure6 2 WX1810H PWR LEDs 1 LEDs for the 100 1000BASE T PoE autosensing Ethe...

Страница 47: ...sensing Ethernet copper port LED Steady green A 1000 Mbps link is present Flashing green Data is being received or transmitted at 1000 Mbps Steady yellow A 100 Mbps link is present Flashing yellow Dat...

Страница 48: ...lying power Flashing green PoE power supply failure or overload has occurred Off No PoE port is supplying power 1000BASE X SFP port LED Steady green A 1000 Mbps link is present on the port Flashing gr...

Страница 49: ...i Contents 7 Appendix C Optional transceiver modules 1 Transceiver module fiber connector and optical fiber views 1 Transceiver module specifications 1...

Страница 50: ...LC connectors Figure7 1 SFP transceiver module Figure7 2 Optical fiber with LC connectors 1 LC connector 2 Optical fiber Transceiver module specifications The transceiver modules that have MM and SM...

Страница 51: ...r mode SMF Fiber diameter 9 m Transmit power 9 5 to 3 dBm Receive sensitivity 20 dBm Saturation 3 dBm Table7 2 SFP GE SX MM850 A specifications Item Specification Central wavelength 850 nm Transmissio...