H3C WAC360 Series Access Controllers

Installation Guide

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
New H3C Technologies Co., Ltd. 
http://www.h3c.com.hk 
 
Document version:6W101-20170616

 

 

Содержание WAC360 Series

Страница 1: ...H3C WAC360 Series Access Controllers Installation Guide New H3C Technologies Co Ltd http www h3c com hk Document version 6W101 20170616...

Страница 2: ...her trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice Every effort has been made i...

Страница 3: ...ents commands and keywords that you enter literally as shown Italic Italic text represents arguments that you replace with actual values Square brackets enclose syntax choices keywords or arguments th...

Страница 4: ...rmation NOTE An alert that contains additional or supplementary information TIP An alert that provides helpful information Network topology icons Represents a generic network device such as a router s...

Страница 5: ...fer from what you have on your device Obtaining documentation To access the most up to date H3C product documentation go to the H3C website at http www h3c com hk To obtain information about installat...

Страница 6: ...t cables 11 Connecting the power adapter 11 Verifying the installation 12 Powering on the device 12 Troubleshooting 14 Power failure 14 No display or garbled display on the configuration terminal 14 L...

Страница 7: ...ii Technical specifications 22 Interface arrangement 23 Appendix B LEDs 24 LEDs 24 Index 25...

Страница 8: ...tes in the voltage range as required Use a screwdriver to fasten screws To prevent condensation perform the following tasks Unpack the device a minimum of half an hour after you move the device from a...

Страница 9: ...perature humidity requirements in the equipment room Temperature Relative humidity 0 C to 40 C 32 F to 104 F 5 to 95 noncondensing Cleanliness Dust buildup on the chassis can result in electrostatic a...

Страница 10: ...ling the device EMI All electromagnetic interference EMI sources from outside or inside of the switch and application system adversely affect the switch in the following ways A conduction pattern of c...

Страница 11: ...ty and temperature are at acceptable levels EMI prevention Take effective measures to protect the power system from the power grid system Separate the protection ground of the device from the groundin...

Страница 12: ...the chassis contact H3C Support for permission Otherwise H3C shall not be liable for any consequence Confirming installation preparations Before you install the device verify that you have read Prepa...

Страница 13: ...le to the grounding system in the equipment room Do not connect it to a fire main or lightning rod No grounding cable is provided with the device Prepare a grounding cable yourself Attaching the ring...

Страница 14: ...2 Use the grounding screw to attach the ring terminal of the grounding cable to the chassis 3 Connect the other end of the grounding cable to the grounding strip Make sure the grounding strip has been...

Страница 15: ...le NOTE Identify the mark on the console port and make sure you are connecting to the correct port The serial ports on PCs do not support hot swapping To connect a PC to an operating device first conn...

Страница 16: ...the Connect using list and click OK Figure 7 Setting the serial port used by the HyperTerminal connection 4 Set Bits per second to 9600 Data bits to 8 Parity to None Stop bits to 1 and Flow control t...

Страница 17: ...Figure 8 Setting the serial port parameters 5 Select File Properties in the HyperTerminal window Figure 9 HyperTerminal window 6 On the Settings tab set the emulation to VT100 or Auto detect and click...

Страница 18: ...et port on the peer device 2 After powering on the device examine the LEDs of the fixed copper Ethernet port For more information about the LED description see Appendix B LEDs Connecting the power ada...

Страница 19: ...he following uses the WAC360 access controller as an example To start the device 1 Power on the device The device initializes its memory and runs BootWare The following information appears on the term...

Страница 20: ...the system enters the system image file reading and self compressing process restart the device Starting to get the main application file flash main bin The main application file is self decompressing...

Страница 21: ...the power system is operating correctly 2 Verify that the console cable has been connected correctly 3 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Par...

Страница 22: ...password when you forget the console login password 1 If password recovery capability is enabled select 6 from the BootWare menu to start the system without loading the system configuration The follow...

Страница 23: ...er privilege level password is restored at a second reboot b Reboot the device and you can directly enter system view If password recovery capability is disabled start the system with the factory defa...

Страница 24: ...Memory Hardware Version is Ver B CPLD Version is 002 Basic Bootrom Version is 1 02 Extend Bootrom Version is 1 02 Subslot 0 WAC360 Hardware Version is Ver B Displaying operational statistics for the d...

Страница 25: ...0x6 CPU Tick High 0x5aa72673 CPU Tick Low TaskName CPU Runtime CPU Tick High CPU Tick Low VIDL 98 6 3e5ae16b TICK 0 0 44f7e49 STMR 0 0 2f5ad1d DrTC 0 0 41c0f7 MCIN 0 0 7cb61 ADJ6 0 0 3a348 IPCB 0 0 4d...

Страница 26: ...splaying the CPU usage of the device Use the display cpu usage command to display the CPU usage statistics for the device H3C display cpu usage Unit CPU usage 2 in last 5 seconds 2 in last 1 minute 2...

Страница 27: ...d division by zero operations by using one of the following methods Reboot The device automatically reboots to recover from the error condition Maintain The device stays in the error condition so you...

Страница 28: ...figuration file for the device you must reboot the device To reboot a device use one of the following methods Reboot the device immediately at the CLI Schedule a reboot at the CLI to occur at a specif...

Страница 29: ...eset button RESET Figure 14 Rear view 1 Grounding screw Technical specifications Table 9 Technical specifications Item Specification Console port One 9600 bps default to 115200 bps Gigabit Ethernet po...

Страница 30: ...lb Operating temperature 0 C to 40 C 32 F to 104 F Relative humidity noncondensing 5 to 95 Interface arrangement The device provides five 100 1000 Base T autosensing Ethernet copper ports GigabitEthe...

Страница 31: ...ected a serious fault Flashing red slowly The Reset button is being pressed for more than 1 second This operation resets the device Flashing red quickly The Reset button is being pressed for more than...

Страница 32: ...ge level password loss 16 Displaying detailed information about the device 18 Displaying operational statistics for the device 17 Displaying the CPU usage of the device 19 Displaying the electronic la...