Figure 19 Fastening the M3 × 23.5 security screw 

 

 

Mounting the AP on a ceiling 

 

CAUTION: 

The ceiling for installing the AP must be less than 18 mm (0.71 in) in thickness, and can bear a load 
of 5 kg (11.02 lb). If you must install the AP on a ceiling not strong enough, use boards to reinforce 
the ceiling. 

 

The installation method for the M3 × 23.5 security screw is similar when the AP is mounted on the 
wall and on the ceiling. 

To mount the AP on a ceiling: 

1. 

Remove the ceiling tile. 

2. 

Place the mounting bracket against the ceiling tile and mark the installation holes on the ceiling 
tile. Drill three holes with a diameter of 6 mm (0.24 in) at the marked positions, as shown in 

Figure 20

. 

Figure 20 Drilling holes in the ceiling tile 

 

 

3. 

Thread the pan-head screws through the installation holes in the mounting bracket and into the 
holes in the ceiling tile. Fasten washers and nuts at the other side of the ceiling to secure the 
mounting bracket to the ceiling, as shown i

Figure 21

. 

Содержание WA6126

Страница 1: ...n a ceiling 8 Connecting the AP to a power source 10 Connecting a PoE power source 10 Connecting a local power source 10 Check after power on 10 Accessing the AP 1 Logging in to the AP from the consol...

Страница 2: ...lling the AP Note that the recommendations do not cover every possible hazardous condition To avoid bodily injury and device damage take adequate safety measures Place the AP in a dry and flat locatio...

Страница 3: ...Accessories provided with the AP Figure 2 Optional accessories for the WA6526E Installation tools When installing the AP you might need the following tools Prepare the installation tools yourself as r...

Страница 4: ...ing at the installation site If the Ethernet interface rate is 2 5 or 5 Gbps use Cat 5e or above network cables For information about the supported interface rates see technical specifications in Hard...

Страница 5: ...t might generate radio frequency RF noise The AP does not hinder people s daily work and life The place is not water seeping water soaking and condensing Mounting the AP IMPORTANT Before mounting the...

Страница 6: ...a wall or ceiling point A 2 T rail installation hole reserved point B 3 Auxiliary hole for securing cables by using cable tie point C 4 Installation hole reserved for electrical outlet box installati...

Страница 7: ...s needed To install a directional antenna put the antenna over the AP front use M2 6 6 mm screws to secure the antenna and then connect the SMA connectors on the antenna to the R SMA connectors on the...

Страница 8: ...lace the mounting bracket against the wall and mark the installation holes on the wall Figure 13 Marking the installation holes on the wall 2 Drill three holes with a diameter of 6 mm 0 24 in and a de...

Страница 9: ...ammering the screw anchor into the wall 4 Thread the M3 23 5 security screw through the security hole in the mounting bracket Make sure the screw does not block the keyhole slot Figure 16 Inserting th...

Страница 10: ...s at the AP rear into the keyhole slots in the mounting bracket and then slide the AP down until it sits securely in the keyhole slots as shown in Figure 18 Figure 18 Attaching the AP to the mounting...

Страница 11: ...d on the wall and on the ceiling To mount the AP on a ceiling 1 Remove the ceiling tile 2 Place the mounting bracket against the ceiling tile and mark the installation holes on the ceiling tile Drill...

Страница 12: ...et Optional You can use a cable tie to secure the cable before attaching the AP to the mounting bracket First thread the cable tie through the auxiliary hole in the mounting bracket leaving the cable...

Страница 13: ...source You can use an AC DC power adapter to connect the AP to a local power source No power adapter is provided with the AP Purchase a power adapter from H3C as required Table 2 describes the power a...

Страница 14: ...ion terminal from the console port CAUTION To connect a PC to the AP first connect the PC end To disconnect a PC from the AP first disconnect the AP end If the PC does not have an RS 232 port but a US...

Страница 15: ...mation is defined for your login Username admin Password h3capadmin Cloud mode Some Intel wireless adapters do not support 802 11ax For clients to detect Wi Fi 6 networks upgrade the driver for the wi...

Страница 16: ...nable WLAN on the configuration terminal and access WLAN H3C_xxxxxx where xxxxxx is the last six bits of the AP s MAC address 2 Visit http wlan h3c com from a browser and then press Enter Visit http m...

Страница 17: ...install Cloudnet App Int from Google Play Store Logging in to the Cloudnet platform To manage the AP from the Cloudnet platform make sure the AP uses an IP address that can reach the external network...

Отзывы: