Chapter 1 Fundamental Configuration Commands
1-3
Example
# Return to the system view from Ethernet interface view.
[VG-Ethernet0] return
[VG]
1.2 Basic System Configuration Commands
1.2.1 clock
Syntax
clock
{
systime
HH:MM:SS
YYYY MM DD
| timezone name
{
add
|
minus
}
HH:MM:SS
}
undo clock timezone
View
System view
Parameter
HH:MM:SS
: Current time of the VG. the hour ranges 0~23; the minute and second
range 0~59.
YYYY
,
MM
and
DD
: Date information of the VG.
YYYY
ranges 1997~2097;
MM
ranges
1~12; the range of
DD
is the actual number of days in the month.
timezone name
: Sets the time zone name and contains 1 to 32 characters.
add HH:MM:SS:
Adds the time zone difference.
minus HH:MM:SS
: Reduces
the time zone difference.
Description
Use the
clock
command to set the system clock of the VG.
Use the
undo clock timezone
command to restore the default system time zone.
By default, if the VG has no hardware real time, then the initial time is 1:00:00, January
1, 1998. But if it has hardware real time, it will set system time to hardware real time.
The timing fails when the VG is powered off, so it is required to set date and time again
for the VG when absolute time is necessary.
Note:
After the VG reboots, the system clock will be restored to the default setting, and the
timezone