Connect one end of the supercapacitor extension cable to the flash card.
CAUTION:
Make sure the extension cable is the correct one. For more information, see
.
{
If the storage controller is installed with an external flash card, connect the supercapacitor
extension cable to the flash card.
Figure 60 Connecting the supercapacitor extension cable to the flash card
{
If the storage controller uses a built-in flash card, connect the supercapacitor extension
cable to the supercapacitor connector on the storage controller.
8.
Install the standard storage controller to the server by using a riser card. For more information,
see "
Installing riser cards and PCIe modules
."
9.
(Optional.) Install the supercapacitor. For more information, see "
."
10.
(Optional.) Connect the other end of the supercapacitor extension cable to the supercapacitor.
For more information about the connection, see "
Connecting the flash card and the
supercapacitor of the power fail safeguard module
."
11.
Connect the drive data cables to the standard storage controller. For more information, see
"
12.
Install the removed fan cage. For more information, see "
."
13.
Install the removed air baffles. For more information, see "
14.
Install the access panel. For more information, see "
15.
Rack-mount the server. For more information, see "
16.
Connect the power cord. For more information, see "
17.
Power on the server. For more information, see "
Verifying the installation
Log in to HDM to verify that the standard storage controller, flash card, and supercapacitor are
operating correctly. For more information, see HDM online help.
Installing a supercapacitor
Guidelines
You can install a supercapacitor in the server chassis, on the air baffle, or in a supercapacitor
container. The priorities of these installation locations are in descending order. If the location with a
high priority is unavailable, use the next available location.
shows the supercapacitors that
can be deployed at each location.