46
Table 7 Supercapacitor extension cable selection
Storage
controller type
Storage controller model
Supercapacitor
Extension
cable P/N
Mezzanine
•
RAID-P430-M1
•
RAID-P430-M2
Supercapacitor of the
Flash-PMC-G2 power fail
safeguard module
N/A
This cable does
not have a P/N.
RAID-P460-M2 BAT-PMC-G3
0404A0TG
RAID-P460-M4 BAT-PMC-G3
0404A0TG
RAID-L460-M4 BAT-LSI-G3 0404A0XH
Standard
•
RAID-LSI-9361-8i(1G)-A1-X
•
RAID-LSI-9361-8i(2G)-1-X
Supercapacitor of the
Flash-LSI-G2 power fail
safeguard module
0404A0SV
•
RAID-LSI-9460-8i(2G)
•
RAID-LSI-9460-8i(4G)
•
RAID-LSI-9460-16i(4G)
BAT-LSI-G3 0404A0VC
RAID-P460-B2 BAT-PMC-G3
0404A0TG
RAID-P460-B4 BAT-PMC-G3
0404A0TG
Installing a Mezzanine storage controller and a power fail
safeguard module
Procedure
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the air baffles as needed. For more information, see "
."
5.
Remove the fan cage. For more information, see "
."
6.
(Optional.) For the ease of installation, remove the riser cards installed on PCIe riser
connectors 1 and 2, if any. For more information, see "
Replacing a riser card and a PCIe
7.
Align the pin holes in the Mezzanine storage controller with the guide pins on the system board.
Insert the guide pins into the pin holes to place the storage controller on the system board, and
then fasten the three captive screws to secure the controller, as shown in