background image

 

34 

LED 

Mark 

Status 

Description 

Alternating between 
yellow and amber 

Both the 2.4 GHz and 5 GHz radios 
have client access. 

 

Содержание SecPath F100-C-A-W

Страница 1: ...H3C SecPath F100 C A W Firewalls Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W101 20200713...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...tax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of option...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...nal Installing a lightning arrester for an AC power module 15 Installing a Wi Fi antenna 15 Installing a 4G antenna 15 Connecting Ethernet cables 16 Connecting an AC power cord 17 Verifying the instal...

Страница 7: ...specifications 28 Chassis views 28 F100 C A3 W F100 C A5 W 28 F100 C A6 WL 29 Technical specifications 30 Dimensions and weights 30 Storage media 30 Power consumption 30 Power specifications 30 Port...

Страница 8: ...n result in data loss data corruption or damage to hardware or software General safety recommendations Make sure the installation position is flat vibration free and away from electromagnetic interfer...

Страница 9: ...ack the firewall carefully to avoid firewall damage Unpack the firewall at least half an hour and power on the firewall at least two hours after you move it from a place below 0 C 32 F to the equipmen...

Страница 10: ...nsing Cleanliness Dust buildup on the chassis might result in electrostatic adsorption which causes poor contact of metal components and contact points especially when indoor relative humidity is low...

Страница 11: ...se one yourself Before you attach an ESD wrist strap make sure the rack or the workbench is reliably grounded To attach the ESD wrist strap 1 Wear the wrist strap on your wrist 2 Lock the wrist strap...

Страница 12: ...the lightning protection capability of the power module To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning strikes route interface cables only indoors If pa...

Страница 13: ...s available at the installation site Ambient temperature Operating 0 C to 45 C 32 F to 113 F Storage 40 C to 70 C 40 F to 158 F Ambient humidity 5 RH to 95 RH noncondensing Cleanness Dust concentratio...

Страница 14: ...ding the power input method and rated input voltage Rack mounting requirements Make sure the cabinet is equipped with a good ventilation system The rack is sturdy enough to support the weight of the f...

Страница 15: ...e same for the H3C SecPath F100 C A W series firewalls This document uses the F100 C A6 WL firewall as an example Figure1 3 Firewall installation flow Determine the installation position Mount the fir...

Страница 16: ...sis bottom with a dry cloth 3 Attach the four rubber feet to the round holes in the chassis bottom 4 Place the firewall with upside up on the workbench Figure1 4 Mounting the firewall on a workbench I...

Страница 17: ...provided M4 mounting bracket screws to secure the mounting brackets to both sides of the firewall Figure1 6 Securing mounting brackets to the firewall 5 Mount the firewall in the rack Use M6 rack scre...

Страница 18: ...to each screw anchor leaving 1 5 mm 0 06 in of the screw exposed to hang the firewall on Make sure the screw anchors and screws are secured in place 5 Hold the firewall with its front panel facing dow...

Страница 19: ...ing conditions available at the installation site Grounding the firewall with a grounding strip If a grounding strip is available at the installation site connect the grounding cable through the groun...

Страница 20: ...minal of the grounding cable 3 Use a Phillips screwdriver to fasten the grounding screw into the grounding hole on the firewall 4 Remove the grounding screw from the grounding point on the rack 5 Use...

Страница 21: ...ace 3 Reinstall the cover and fasten the screw on the cover Figure1 11 Installing a SIM card If you want to replace the SIM card perform the following steps 1 Remove the cover form the SIM card slot 2...

Страница 22: ...the equipment room For more information about how to install and maintain a lightning arrester for AC power modules see the documents provided with the lightning arrester Installing a Wi Fi antenna 1...

Страница 23: ...net cables The Ethernet copper ports on the firewall support auto MDI MDIX You can use either straight through or cross over network cables to connect the ports For more information about Ethernet twi...

Страница 24: ...e AC input power receptacle on the firewall 3 Pull the power cord retainer clip downwards and secure the connector to the power receptacle 4 Connect the other end of the power cord to an AC power sour...

Страница 25: ...ring on the firewall so you can quickly shut power off when an electrical accident occurs Before powering on the firewall verify that the following conditions are met The power cord and grounding cabl...

Страница 26: ...boot E9524P11 bin Done Image file flash f1010fww cmw710 boot E9524P11 bin is self decompressing Done System image is starting Cryptographic algorithms tests passed Line con0 is available Press ENTER...

Страница 27: ...PC and the firewall are reachable to each other The PC must use a different IP address than the Ethernet management interface 3 Start a browser enter 192 168 0 1 in the address bar and press Enter 4...

Страница 28: ...ng the software and hardware version information of the firewall Use the display version command to display the software and hardware version information of the firewall Sysname display version H3C Co...

Страница 29: ...ame DEVICE_SERIAL_NUMBER Firewall serial number MAC_ADDRESS MAC address of the firewall MANUFACTURING_DATE Manufacturing date of the firewall VENDOR_NAME Vendor name Displaying the CPU usage of the fi...

Страница 30: ...s Part 1 is used for kernel codes kernel management and ISSU functions Part 2 can be allocated and used for such tasks as running service modules and storing files The size of part 2 equals the total...

Страница 31: ...tistics of multiple functional modules of the firewall Save the operational statistics of each functional module of the firewall Sysname display diagnostic information Save or display diagnostic infor...

Страница 32: ...at the CLI You can set a time at which the firewall can automatically reboot or set a delay so that the firewall can automatically reboot within the delay Power on the firewall after powering it off w...

Страница 33: ...thing or garbled text when the firewall is powered on Solution To resolve the issue 1 Verify that the power system is operating correctly 2 Verify that the console cable is correctly connected 3 Verif...

Страница 34: ...amine the software loading process displayed on the TeraTermPro or PuTTY for errors Possible errors include Inconsistent baud rates configured for XMODEM and the TeraTermPro or PuTTY Incorrect IP addr...

Страница 35: ...1 Reset button 2 USB port 3 Console port 4 10 100 1000BASE T copper ports 5 LEDs 6 Management Ethernet port GE1 0 0 Rear panel The F100 C A3 W F100 C A5 W firewall provides one AC input power recepta...

Страница 36: ...agement Ethernet port GE1 0 0 Rear panel The F100 C A6 WL firewall provides one AC input power receptacle two 4G antenna ports one SIM card slot and one WLAN module Figure1 19 Rear panel 1 Grounding s...

Страница 37: ...Item Specification Flash 16MB NOR flash 512MB NAND flash Memory 2GB DDR3 Power consumption Table1 13 Power consumption Model System power consumption F100 C A3 W F100 C A5 W 25 W F100 C A6 WL 30 W Po...

Страница 38: ...49 21 ft Services Connection to an ASCII terminal Connection to the serial port of a local PC running the terminal emulation program CLI GE copper port Table1 17 GE copper port specifications Item Spe...

Страница 39: ...antenna connectors and is compliant with 802 11a b g n ac It supports 2 4 GHz and 5 GHz bands Table1 18 WLAN module ports Item Specification Connector RJ 45 Port One console port Port standard Console...

Страница 40: ...red on or has failed Slow flashing green The firewall is operating correctly Fast flashing green The firewall is loading software Power status LED PWR Off The power system is faulty Steady green The p...

Страница 41: ...34 LED Mark Status Description Alternating between yellow and amber Both the 2 4 GHz and 5 GHz radios have client access...

Страница 42: ...thernet twisted pair cable consists of four pairs of insulated copper wires twisted together Every wire uses a different color and has a diameter of about 1 mm 0 04 in A pair of twisted copper cables...

Страница 43: ...lthough they provide better EMI prevention performance than UTPs so in most LANs UTPs are commonly used An Ethernet twisted pair cable connects network devices through the RJ 45 connectors at the two...

Страница 44: ...s Pin 10BASE T 100BASE TX 1000BASE T Signal Function Signal Function 1 Tx Sends data BIDA Bi directional data cable A Straight through cable white orange orange white green blue white blue green white...

Страница 45: ...nal data cable C 8 Reserved N A BIDC Bi directional data cable C To ensure normal communication the pins for sending data on one port must correspond to the pins for receiving data on the peer port Wh...

Страница 46: ...one another Insert the wires into the RJ 45 connector and make sure the wires extend to the front of the RJ 45 connector and make good contact with the metal contacts in the RJ 45 connector and in th...

Отзывы: