2-8
Figure2-4 Installing the mounting brackets at the port side
(1) Power supply handle
(2) Mounting bracket
(3) Cable management bracket
Figure2-5 Installing the mounting brackets at the power supply side
(1) Power supply handle
(2) Mounting bracket
(3) Cable management bracket
Rack requirements
To mount the switch in a 19-inch rack, the rack must meet the requirements in
Table2-2 Rack requirements
Mounting
bracket
installation
position
Chassis dimensions
Distance
between the
front and rear
rack posts
Rack requirements
Mounting
brackets installed
near the port side
•
Width
—440 mm (17.32 in)
•
Height
—88.1 mm (3.47 in)/2
RU
•
Depth
—643 mm (25.31 in)
540 mm (21.26 in) for the
chassis
92 mm (3.62 in) for the
mounting brackets
26 mm (1.02 in) for the
power supply/fan tray
handles
501 to 778 mm
(19.72 to 30.63 in)
•
A minimum of 800 mm
(31.50 in) in depth
(recommended)
•
A minimum of 130 mm
(5.12 in) between the
front rack posts and
the front door
•
A minimum of 630 mm
(24.80 in) between the
front rack post and the
rear door.
77mm (3.03 in)
88.1mm
(3.47 in)
3
525mm
(20.67 in)
26mm
(1.02 in)
1
2
15mm
(0.59 in)
88.1mm
(3.47 in)
538mm
(21.18 in)
26mm
(1.02 in)
2
92mm
(3.62 in)
1
3