2
Table 2
Power module specifications
Item
LSUM1AC1200
specifications
LSUM1AC2500
specifications
LSUM1DC2400
specifications
Rated input
voltage range
100 VAC to 240 VAC @
50/60 Hz
100 VAC to 240 VAC @
50/60 Hz
–48 VDC to –60 VDC
Rated output
voltage
12 VDC
12 VDC
12 VDC
Maximum input
current
16 A
16 A
60 A
Maximum output
current
100 A
•
100 A (110 VAC)
•
208 A (220 VAC)
200 A
Maximum output
power
1200 W
•
1200 W (110 VAC)
•
2500 W (220 VAC)
2400 W
Quantity 1
to
6
Safety recommendations
To avoid equipment damage or bodily injury caused by improper use, read the following safety
recommendations before installation. Note that the recommendations do not cover every possible
hazardous condition.
•
To prevent ESD damage, always wear an ESD wrist strap and make sure it is reliably grounded
before you touch the switch, cards, or PCB.
•
Do not install the switch, FRUs, or power cords when the switch is powered on.
•
To avoid equipment damage or bodily injury, make sure the switch is reliably grounded before
powering on the switch.
•
To ensure good ventilation, install a blank filler panel in an unused slot.
Figure 2
Attaching an ESD wrist strap