Installation Manual
H3C S7500E Series Ethernet Switches
Chapter 1 Product Overview
1-49
Table 1-74
Description of the CFS LED
Status
Description
OFF
No CF card is in position.
ON
The CF card is in position.
z
GE/FE SFP ports
Table 1-75 presents the specifications of the GE/FE ports.
Table 1-75
Specifications of the GE/FE SFP ports
Item
Specifications
Connector type
SFP
Number of connectors
12
Standards
z
IEEE 802.3-2005
z
IEEE 802.1D-2004
z
IEEE 802.1Q-2003
z
IEEE 802.1X-2004
Pluggable module type
z
Gigabit SFP module
z
100 Mbps SFP module
Refer to “Appendix A List of Pluggable Modules.”
Table 1-76 describes the status LEDs of the 1000Base-X-SFP/100Base-FX-SFP ports.
Table 1-76
Description of the status LEDs of the 1000Base-X-SFP/100Base-FX-SFP
ports
LED
Description
LINK/ACT
z
OFF: No link is present.
z
ON: A link is present.
z
Blinking: Data is being transmitted or received.
z
Console port
Using an RJ-45 connector, the console port can be connected through a regular
asynchronous serial cable directly to a computer for system debugging, configuration,
maintenance, management, and host software loading, or to a modem for remote
system debugging, configuration, maintenance and management.