3
Figure 3 Connecting the console port to the terminal
Setting terminal parameters
To configure and manage the switch through the console port, you must run a terminal emulator
program, TeraTermPro or PuTTY, on your configuration terminal. You can use the emulator program
to connect a network device, a Telnet site, or an SSH site. For more information about the terminal
emulator programs, see the user guides for these programs.
The following are the required terminal settings:
•
Bits per second
—9,600.
•
Data
bits
—8.
•
Stop
bits
—1.
•
Parity
—None.
•
Flow
control
—None.
Powering on the switch
Before powering on the switch, verify that the following conditions are met:
•
The switch has been steadily mounted.
•
All the cards have been correctly installed.
•
All the network cables, power cords, and grounding cables have been correctly connected.
•
The voltage of power supply can meet the requirements of the switch.
•
The console cable has been correctly connected. The configuration terminal has been started,
and the terminal parameters have been configured.
To power on the switch:
Turn on the power supply and power modules of the switch to power on the switch.