background image

Step 

Command 

Remarks 

1. 

Enter system view. 

system-view 

N/A 

2. 

Enter the view of any 10-GE 
breakout interface. 

interface interface-type 
interface-number

 

N/A 

3. 

Combine the four 10-GE 
breakout interfaces into a 
40-GE interface. 

using fortygige 

By default, a 40-GE interface is 
not split and operates as a single 
interface. 

 

Changing the interface type of 100-GE interfaces in batches 

 

IMPORTANT: 

  This feature is not supported on non-default MDCs. 

  The interfaces to be changed in batches must be on the same card. 

 

Restrictions and guidelines 

This feature is supported only on the LSQM1CQGS12SG0, and LSQM1TGS24QSFD0  interface 
modules. 

On the LSQM1CQGS12SG0 interface modules, after you change each group of 40-GE interfaces to 
100-GE interfaces, only interfaces 1, 4, 7, and 10 are available. On the LSQM1TGS24QSFD0 
interface modules, after you change each group of 40-GE interfaces to 100-GE interfaces, only 
interface 25 is available. 

Reboot the interface module after you configure this feature. Do not assign the changed interfaces to 
any non-default MDC before rebooting the interface module. 

For this configuration to survive a reboot, save the running configuration before rebooting the device. 

Changing 100-GE interfaces to 40-GE interfaces in batches 

To improve network flexibility, you can change 100-GE interfaces to 40-GE interfaces in batches. For 
this configuration to succeed, you must specify the available interface numbers. 

To change 100-GE interfaces to 40-GE interfaces in batches: 

 

Step 

Command 

Remarks 

1. 

Enter system view.

 

system-view 

N/A 

2. 

Change 100-GE interfaces to 
40-GE interfaces. 

using 
fortygige-from-hundredgige 
interface 

interface-type 

interface-number

 [ 

to 

interface-type 
interface-number

 ] } &<1-24>

 

N/A 

 

Changing 40-GE interfaces to 100-GE interfaces in batches 

To improve network flexibility, you can change 40-GE interfaces to 100-GE interfaces in batches. For 
this configuration to succeed, make sure all interfaces in one group are specified in this 
configuration.  

On the LSQM1CQGS12SG0 interface modules, three continuous interfaces starting from 1 are 
organized into one group. On the LSQM1TGS24QSFD0 interface modules, two  continuous 
interfaces starting from 1 are organized into one group. 

To change 40-GE interfaces to 100-GE interfaces in batches: 

 

Содержание S7500X Series

Страница 1: ...H3C S7500X Switch Series Interface Configuration Guide New H3C Technologies Co Ltd http www h3c com Software version Release 7585P05 and later versions Document version 6W100 20200529...

Страница 2: ...H3C Technologies Co Ltd any trademarks that may be mentioned in this document are the property of their respective owners Notice The information in this document is subject to change without notice A...

Страница 3: ...optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical ba...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...i Contents Bulk configuring interfaces 1 Configuration restrictions and guidelines 1 Configuration procedure 1 Displaying and maintaining bulk interface configuration 2...

Страница 7: ...terface range the longer the command execution time The maximum number of interface range names is limited only by the system resources To guarantee bulk interface configuration performance configure...

Страница 8: ...ace range to enter the interface range view 3 Optional Display commands available for the first interface in the interface range Enter a question mark at the interface range prompt N A 4 Use available...

Страница 9: ...rnet interface 9 Enabling link flapping protection on an interface 10 Configuring FEC 11 Enabling loopback testing on an Ethernet interface 12 Configuring generic flow control on an Ethernet interface...

Страница 10: ...r You can connect the interface to a PC for software loading and system debugging or connect it to a remote NMS for remote system management Restrictions and guidelines The management Ethernet interfa...

Страница 11: ...faces see Configuring a Layer 3 Ethernet interface or subinterface Configuring a combo interface single combo interface A combo interface is a logical interface that physically comprises one fiber com...

Страница 12: ...ot the interface card to make the configuration take effect Do not assign the changed interfaces to any non default MDC before rebooting the interface card To split a 40 GE interface into four 10 GE b...

Страница 13: ...on default MDC before rebooting the interface module For this configuration to survive a reboot save the running configuration before rebooting the device Changing 100 GE interfaces to 40 GE interface...

Страница 14: ...with copper port transceiver modules installed on the following interface modules FD interface modules SC interface modules LSQM2GP24TSSC0 LSQM2GP44TSSC0 LSQM2GT24PTSSC0 LSQM2GT24TSSC0 LSQM2GT48SC0 L...

Страница 15: ...ed bandwidth in kbps is the interface baud rate divided by 1000 7 Restore the default settings for the Ethernet interface default N A 8 Bring up the Ethernet interface undo shutdown B y default an Eth...

Страница 16: ...oups see Network Management and Monitoring Configuration Guide To configure the link mode of an Ethernet interface Step Command Remarks 1 Enter system view system view N A 2 Enter Ethernet interface v...

Страница 17: ...press only link down events only link up events or both If an event of the specified type still exists when the suppression interval expires the system reports the event to the CPU Configuration restr...

Страница 18: ...e the interface does not report its state changes to the CPU For state change events the interface only generates SNMP traps and log messages Reuse limit When the accumulated penalty decreases to this...

Страница 19: ...edure To configure dampening on an Ethernet interface Step Command Remarks 1 Enter system view system view N A 2 Enter Ethernet interface view interface interface type interface number N A 3 Enable da...

Страница 20: ...ce interface type interface number N A 4 Enable link flapping protection on the Ethernet interface port link flap protect enable interval interval threshold threshold By default link flapping protecti...

Страница 21: ...does not forward data traffic The shutdown port up mode and loopback commands are mutually exclusive Enabling loopback testing on an interface will invalidate the voice VLAN MAC learning limit MAC ad...

Страница 22: ...the flow control command at the other end To enable both ends of a link to handle traffic congestion configure the flow control command at both ends Configuration restrictions and guidelines This feat...

Страница 23: ...type interface number N A 3 Set the statistics polling interval for the Ethernet interface flow interval interval By default the statistics polling interval is 300 seconds To display the interface st...

Страница 24: ...rnet port does not support this feature if the port is shut down by a protocol or by using the shutdown command A fiber Ethernet port does not support this feature if the port joins an aggregate group...

Страница 25: ...ow these restrictions and guidelines For the traffic suppression result to be determined do not configure storm control together with storm suppression for the same type of traffic For more informatio...

Страница 26: ...blocked traffic drops below the lower threshold the interface does not automatically come up To bring up the interface use the undo shutdown command or disable the storm control feature You can confi...

Страница 27: ...outputs log messages when monitored traffic exceeds the upper threshold or drops below the lower threshold after exceeding the upper threshold 7 Optional Enable the Ethernet interface to send storm co...

Страница 28: ...terface has eight pins each of which plays a dedicated role For example pins 1 and 2 transmit signals and pins 3 and 6 receive signals You can use both crossover and straight through Ethernet cables t...

Страница 29: ...result includes the cable s status and some physical parameters If any fault is detected the test result shows the length from the local port to the faulty point To test the cable connection of an Eth...

Страница 30: ...Ethernet interface or subinterface mtu size The default setting is 1500 bytes Displaying and maintaining an Ethernet interface or subinterface Execute display commands in any view and reset commands...

Страница 31: ...ethernet statistics slot slot number In IRF mode Display the Ethernet module statistics display ethernet statistics chassis chassis number slot slot number Clear interface or subinterface statistics...

Страница 32: ...ing loopback null and inloopback interfaces 1 Configuring a loopback interface 1 Configuring a null interface 1 Configuring an inloopback interface 2 Displaying and maintaining loopback null and inloo...

Страница 33: ...device itself so the device does not forward these packets Using a loopback interface in dynamic routing protocols With no router ID configured for a dynamic routing protocol the system selects the hi...

Страница 34: ...e created by the system which cannot be configured or deleted The physical layer and link layer protocol states of an inloopback interface are always up All IP packets sent to an inloopback interface...

Отзывы: