20
Count: 3
Flow table: 0
Flow entry: 1, 2, 3
Meter entry 200 information:
Meter flags: KBPS
Band 1 information
Type: drop, rate: 10240kbps, burst size: 655360kb
Byte count: --, packet count: --
Referenced information:
Count: 0
Table 8 Command output
Field Description
Group entry count
Total number of meter entries included in the OpenFlow instance.
Meter flags
Flags configured for the meter:
•
KBPS
—The rate value is in kbps.
•
PKTPS
—The rate value is in pps.
•
BURST
—The burst size field in the band is used and the length of the
packet or byte burst is determined by the burst size.
•
STATS
—Meter statistics are collected.
Band
Bands included in the meter.
Type
Type of the band:
•
drop
—
Discard the packet.
•
dscp remark
—
Modify the drop precedence of the DSCP field in the IP
header of the packet.
Rate
Rate value above which the corresponding band applies to packets.
Burst size
Length of the packet or byte burst to consider for applying the meter.
Byte count
Number of bytes processed by a band.
If this field is not supported, the field displays two hyphens (
--
).
packet count
Number of packets processed by a band.
If this field is not supported, the field displays two hyphens (
--
).
Referenced information
Information about the meter entry referenced by flow entries.
Count
Total number of flow entries that reference the meter entry.
Flow table
Flow table to which the flow entries that reference the meter entry belong.
Flow entry
Flow entries that reference the meter entry.
display openflow summary
Use
display openflow summary
to display brief OpenFlow instance information.
Syntax
display openflow instance summary
Views
Any view