Installation Manual
H3C S7500E Series Ethernet Switches
Chapter 4 System Commissioning
4-2
1)
Start PC and run the terminal emulator (such as Terminal on Windows3.1, and the
HyperTerminal on Windows95/Windows98/Windows 2000/Windows NT/Windows
ME/Windows XP).
2)
Set the parameters for Windows XP HyperTerminal as follows:
z
Bits per second: 9600
z
Data bits: 8.
z
Parity: None
z
Stop bits:1
z
Flow control: None
z
Terminal emulation: VT100
The procedure is as follows:
Select
Start
>
Programs
/
All
Programs
>
Accessories
>
Communications
>
HyperTerminal
to enter the HyperTerminal window to establish a new connection and
the system will pop up the
Connection Description
dialog box.
Figure 4-2
Connection description of HyperTerminal
Type the name of the new connection and click
OK
. Then there pops up the interface as
shown in the following figure. Select the serial port to be used from
Connect using
drop-down list box.