H3C s5800 series Скачать руководство пользователя страница 25

24 

For the S5800-60C-PWR, use the PoE power according to the PoE power supply scheme. For 

information about the power supply compatibility, see 

H3C S5800-60C-PWR Ethernet Switch Hot 

Swappable Power Module Ordering Guide

2.

 

Execute the following commands to display power supply information: 

a.

 

Execute the 

display poe device

 command in any view to display PSE information, and check 

the 

faulty

 field to identify PSE problems.

 

<Sysname> display poe device 

PSE ID  SlotNo SubSNo PortNum  MaxPower(W)  State   Model 

 4      1      0      24       370          faulty  LSW124POED-M 

The output shows that the PSE has problems.  

b.

 

Execute the 

poe update

 command to upgrade the PSE processing software in service. 

<Sysname> system-view 

[Sysname] poe update full ver_3_9_0_release.bin pse 4 

This command will fully update firmware on the specific PSE(s), Continue? [Y/N]:y 

System is downloading firmware into the hardware. Please wait  

Update firmware on the specific PSE(s) successfully! 

The output shows that the PSE processing software has been upgraded. 

c.

 

Execute the 

display poe device

 command again to display PSE information, and check the 

on

 

or 

off

 field for the PSE state. 

[Sysname] display poe device 

PSE ID  SlotNo SubSNo PortNum  MaxPower(W)  State   Model 

 4      1      0      24       370          off     LSW124POED-M 

The output shows that the PSE problem has been resolved. 

d.

 

Execute the 

display poe pse

 command in any view to display detailed PSE information. Verify 

the following: 

 

The current power, average power, and peak power of the PSE are correct. 

 

Nonstandard PD detection by the PSE is enabled. 

[Sysname] display poe pse 

 PSE ID                           : 4 

 PSE Slot No                      : 1 

 PSE SubSlot No                   : 0 

 PSE Model                        : LSW124POED-M 

 PSE Power Enabled                : enabled 

 PSE Power Priority               : - 

 PSE Current Power                : 0        W  

 PSE Average Power                : 0        W 

 PSE Peak Power                   : 0        W 

 PSE Max Power                    : 370      W 

 PSE Remaining Guaranteed         : 370      W 

 PSE CPLD Version                 : -  

 PSE Software Version             : 390 

 PSE Hardware Version             : 57603 

 PSE Legacy Detection             : disabled 

 PSE Utilization-threshold        : 80 

 PSE Pd-policy Mode               : disable 

 PSE PD Disconnect Detect Mode    : AC 

Содержание s5800 series

Страница 1: ...ngzhou H3C Technologies Co Ltd All rights reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co Ltd...

Страница 2: ...n 8 Link aggregation failure 8 Symptom 8 Troubleshooting flowchart 9 Solution 9 Related commands 10 Troubleshooting ports 13 Link up failure on a port 13 Symptom 13 Troubleshooting flowchart 13 Soluti...

Страница 3: ...ii Troubleshooting flowchart 23 Solution 23 Related commands 25...

Страница 4: ...enough hardware resource message Solution To resolve this problem 1 Execute the display acl resource command and then check the Remaining field for ACL resources insufficiency If this field displays...

Страница 5: ...n policy Global display qos policy global Control plane display qos policy control plane slot slot number b If the QoS policy does not contain a class behavior association associate the traffic behavi...

Страница 6: ...re are any configuration errors reconfigure the ACL 3 If the problem persists contact H3C Support Related commands This section lists the commands that you might use for troubleshooting ACLs Command D...

Страница 7: ...4 Troubleshooting IRF This section provides troubleshooting information for common problems with IRF IRF fabric establishment failure Symptom An IRF fabric cannot be established...

Страница 8: ...ings or reconnect physical ports IRF fabric size allowed Physical IRF connections consistent with IRF port bindings No Resolved IRF links up Bring up physical ports activate IRF port configuration Res...

Страница 9: ...RF port bindings or reconnect the physical IRF ports 4 Verify that IRF links are 10 Gbps a Verify that the transceiver modules or cables for IRF connection are labeled with 10Gbps or SFP b Replace a t...

Страница 10: ...to verify that each IRF port has at least one physical port in up state display irf Displays IRF fabric information including the member ID role priority bridge MAC address and description of each IRF...

Страница 11: ...ooting Ethernet link aggregation This section provides troubleshooting information for common problems with Ethernet link aggregation Link aggregation failure Symptom Link aggregation does not operate...

Страница 12: ...urations class two configurations same as the reference port Set attribute configurations class two configurations same as the reference port No Yes Set no more than 8 member ports Yes No More than 8...

Страница 13: ...the configurations of the peer member ports b Configure the peer member ports to make sure the peer ports have the same attribute configurations and class two configurations as the peer port of the re...

Страница 14: ...o resolve the problem Physically connected Shut down Check the port connection undo shutdown No Yes Yes No Cable is correct or transceiver module matches wavelength Replace the cable or fiber No Yes S...

Страница 15: ...l use the display transceiver interface command to display the transceiver module information Sysname display transceiver interface ten gigabitethernet 1 1 1 Ten GigabitEthernet1 1 1 transceiver infor...

Страница 16: ...nds This section lists the commands that you might use for troubleshooting ports Command Description display device Displays device information display interface brief Displays brief interface informa...

Страница 17: ...ing error packets No Yes Yes Locate the reasons of the failure End No Yes Layer 2 packet loss Packets filtered by ACLs or QoS policies Locate the reasons and solve the failure Port blocked No Yes Port...

Страница 18: ...failure To test and solve such a failure replace the transceiver module fiber or twisted pair with a good one Inconsistent configurations Verify that the configurations such as speed and duplex mode o...

Страница 19: ...he display link aggregation verbose command to identify the port status When the port is an Unselected port it cannot forward traffic Locate the reasons why the port is in Unselected state For example...

Страница 20: ...ts contact H3C Support Related commands This section lists the commands that you might use for troubleshooting Layer 2 packet loss failure Command Description display interface Displays Ethernet inter...

Страница 21: ...ollected for an interface on a per queue basis Layer 3 forwarding failure Symptom Packet loss occurs when the switch forwards packets to a different network Troubleshooting flowchart Figure 6 Troubles...

Страница 22: ...ncorrect route entries exist troubleshoot the protocol that learns the route entries If route entries are correct but the problem persists contact H3C Support Related commands This section lists the c...

Страница 23: ...between the SFP port and the IRF port and re plug in the SFP module to the SFP port If the SFP port is not bound to an IRF port perform step 1 3 If the problem persists run the display diagnostic info...

Страница 24: ...ical ports bound to the IRF ports on each IRF member device The new member IDs take effect at reboot PoE power supply anomaly Symptom The PoE device cannot supply power correctly Troubleshooting flowc...

Страница 25: ...Update firmware on the specific PSE s successfully The output shows that the PSE processing software has been upgraded c Execute the display poe device command again to display PSE information and ch...

Страница 26: ...Class 0 Port Detection Status disabled Port Power Mode signal Port Current Power 0 mW Port Average Power 0 mW Port Peak Power 0 mW Port Max Power 30000 mW Port Current 0 mA Port Voltage 0 0 V Port PD...

Отзывы: