40
Item S5130-52S-EI S5130-28F-EI S5130-52TP-EI
100/1000Base-
X SFP ports
N/A
24 (The eight
highest-numbered SFP
ports and their
corresponding
10/100/1000Base-T
autosensing Ethernet ports
form combo interfaces.)
N/A
SFP+ ports
4
4
2
Power module
slots
N/A
2, on the rear panel
N/A
Input voltage
•
AC power source:
{
Rated voltage:
100 VAC to 240
VAC @ 50 or 60
Hz
{
Max voltage: 90
VAC to 264 VAC
@ 47 to 63 Hz
•
DC power source:
–48 VDC power
source in the
equipment room or
an RPS
(recommended H3C
models: RPS800-A
or RPS1600-A)
{
Rated voltage:
–48 VDC to –60
VDC
{
Max voltage: –36
VDC to –72 VDC
The input voltage depends
on the hot-swappable
power module model, as
shown in
•
AC power source:
{
Rated voltage: 100
VAC to 240 VAC @
50 or 60 Hz
{
Max voltage: 90 VAC
to 264 VAC @ 47 to
63 Hz
•
DC power source: –48
VDC power source in
the equipment room or
an RPS (recommended
H3C models: RPS800-A
or RPS1600-A)
{
Rated voltage: –48
VDC to –60 VDC
{
Max voltage: –36
VDC to –72 VDC
Minimum power
consumption
•
AC: 38 W
•
DC: 38 W
•
AC: 30 W
•
DC: 38 W
•
AC: 36 W
•
DC: 36 W
Maximum
power
consumption
•
AC: 45 W
•
DC: 50 W
•
AC: 60 W
•
DC: 68 W
•
AC: 54 W
•
DC: 54 W
Chassis
leakage current
compliance
•
UL60950-1
•
EN60950-1
•
IEC60950-1
•
GB4943.1
Melting current
of power
module fuse
•
AC-input:
10
A/250
V
•
DC-input: 5 A/250 V
•
AC-input: 6.3 A/250 V
•
DC-input: 8 A/250 V
•
AC-input: 10 A/250 V
•
DC-input: 5 A/250 V
Operating
temperature
0°C to 45°C (32°F to 113°F)
Operating
humidity
5% to 95%, noncondensing
Fire resistance
compliance
•
UL60950-1
•
EN60950-1
•
IEC60950-1
•
GB4943.1