H3C S3100V3-EI Series Скачать руководство пользователя страница 57

2-20 

 

The S3100V3-EI non-PoE switches do not have a mode LED. 

Table3-12

 describes the 

10/100BASE-T and 10/100/1000BASE-T autosensing Ethernet ports LEDs on these switches.  

Table3-12 10/100BASE-T and 10/100/1000BASE-T autosensing Ethernet port LED 
description 

LED status 

Description 

Steady green 

A link is present on the port. 

Flashing green 

The port is sending or receiving data. 

Off 

No link is present on the port. 

 

 

 

Содержание S3100V3-EI Series

Страница 1: ...H3C S3100V3 EI Switch Series Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W106 20210427...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...se syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...ccessing the switch for the first time 3 17 Connecting the switch to a configuration terminal 3 17 Connecting a DB9 to RJ45 console cable 3 17 Connecting a USB to RJ45 console cable 3 18 Setting termi...

Страница 7: ...ii...

Страница 8: ...0V3 28TP PWR EI LS 3100V3 28TP PWR EI LS 3100V3 28TP PWR EI GL NOTE Switches of the same model but different PIDs might differ in hardware and software features You can view the PID of a switch on the...

Страница 9: ...nd metal corrosion Lasting low relative humidity can cause washer contraction and ESD and cause issues including loose mounting screws and circuit failure High temperature can accelerate the aging of...

Страница 10: ...gas concentrations in the equipment room at their average values Make sure the corrosive gas concentrations do not exceed 30 minutes per day at their maximum values To control corrosive gases use the...

Страница 11: ...r stations and high frequency devices to make sure the EMI levels do not exceed the compliant range Use electromagnetic shielding when necessary For example use shielded interface cables To prevent si...

Страница 12: ...consequence Figure2 1 Hardware installation flow Installing the switch in a 19 inch rack Mounting brackets Table2 2 describes mounting brackets applicable to the switch Start Install the switch Groun...

Страница 13: ...ackets 1 Screw hole for attaching the bracket to the switch 2 Screw hole for attaching the bracket to the rack post Attaching the mounting brackets to the switch 1 Align one mounting bracket with the...

Страница 14: ...ing bracket C S3100V3 10TP EI switch Rack mounting the switch This task requires two people To mount the switch in the rack 1 Wear an ESD wrist strap and make sure it makes good skin contact and is re...

Страница 15: ...rackets to the rack with M6 screws M6 screws are provided only for switches shipped with mounting brackets For switches not shipped with mounting brackets prepare M6 screws yourself 5 Verify that the...

Страница 16: ...holes in the chassis bottom 4 Place the switch with upside up on the workbench Mounting the switch on a wall CAUTION Before drilling holes in a wall make sure no electrical lines exist in the wall Le...

Страница 17: ...all 1 2 Drill two holes with a diameter of 6 mm 0 24 in and a depth of 25 mm 0 98 in at the marked locations Hammer the screw anchors into the wall and use a Phillips screwdriver to fasten the screw i...

Страница 18: ...h a grounding strip Grounding the switch with a grounding conductor buried in the earth ground NOTE The chassis views and power module and grounding terminal positions in the following figures are for...

Страница 19: ...Hook the grounding cable to the post on the grounding strip and use the hex nut to secure the cable to the post Figure2 14 Connecting the grounding cable to a grounding strip 1 Grounding post 2 Ground...

Страница 20: ...cord connection procedures at a glance Switch model Available power source Connection procedure reference S3100V3 10TP EI S3100V3 18TP EI S3100V3 28TP EI S3100V3 52TP EI S3100V3 10TP PWR EI S3100V3 20...

Страница 21: ...he handle near the AC power receptacle See Figure2 17 3 Connect the other end of the power cord to an AC power source Figure2 16 Connecting the AC power cord 1 Figure2 17 Connecting the AC power cord...

Страница 22: ...t carrying capacity over 6A for an S3100V3 20TP PWR EI DC switch and a cable with a current carrying capacity over 1A for an S3100V3 18TP EI DC or S3100V3 28TP EI DC switch The power cord wiring color...

Страница 23: ...ace for heat dissipation around the switch and the rack or workbench is stable The grounding cable is securely connected The correct power source is used The power cords are correctly connected All th...

Страница 24: ...nsole cable from H3C Table3 1 Connection methods and console cables Connection method Console cable type Configuration terminal side connector Switch side connector Using the serial console port for c...

Страница 25: ...r example a PC by using a DB9 to RJ45 console cable 1 Plug the DB 9 female connector of the DB9 to RJ45 console cable to the serial port on the PC 2 Connect the RJ 45 connector to the serial console p...

Страница 26: ...ck the following link or copy it to the address bar on your browser and download the USB to RJ45 console driver http www h3c com en home USB_to_RJ45_Console 2 View the TXT file Read me in the Windows...

Страница 27: ...network device a Telnet site or an SSH site For more information about the terminal emulator programs see the user guides for these programs Configure the terminal parameters as follows Bits per seco...

Страница 28: ...erface and menu options differ with software versions For more information about Boot ROM menu options see the software matching release notes for the device 3 After the switch starts up you can acces...

Страница 29: ...ric setup Plan the installation site and IRF fabric setup parameters Planning IRF fabric size and the installation site Identifying the master switch and planning IRF member IDs Planning IRF topology...

Страница 30: ...olution for a data center Identifying the master switch and planning IRF member IDs Determine which switch you want to use as the master for managing all member switches in the IRF fabric An IRF fabri...

Страница 31: ...ilability NOTE The following figures use the SFP ports on the S3100V3 28TP PWR EI switch as an example For the ports that can be used for IRF connections see Table4 1 Figure4 2 IRF fabric in daisy cha...

Страница 32: ...e the following cables to connect the IRF physical ports on the switches 10 100 1000BASE T autosensing Ethernet port Category 5 or above twisted pair cable SFP port GE SFP fiber transceiver module and...

Страница 33: ...on You can install IRF member switches in different racks side by side to deploy a top of rack ToR solution Figure4 6 shows an example for connecting four top of rack IRF member switches by using SFP...

Страница 34: ...and Network Cables Installation Guide Verifying the IRF fabric setup To verify the basic functionality of the IRF fabric after you finish configuring basic IRF settings and connecting IRF ports 1 Log...

Страница 35: ...is in position or working normally Steady yellow RPS power input is normal but AC input has failed or AC input is not connected Off No RPS is connected AC input failure Symptom The system status LED...

Страница 36: ...re of the switch is in the acceptable range and the power module has good ventilation Over temperature can cause the power module to stop working and enter the protection state 6 If the issue persists...

Страница 37: ...cable has been connected correctly 4 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None 5 Verify that the console...

Страница 38: ...EI DC 2 9 S3100V3 52TP EI 2 10 S3100V3 10TP PWR EI 2 11 S3100V3 20TP PWR EI 2 11 S3100V3 20TP PWR EI DC 2 12 S3100V3 28TP PWR EI 2 13 3 Ports and LEDs 2 14 Ports 2 14 Console port 2 14 10 100BASE T a...

Страница 39: ...3100V3 28TP EI LS 3100V3 28TP EI LS 3100V3 28TP EI GL LS 3100V3 28TP EI H1 S3100V3 28TP EI DC LS S3100V3 28TP EI DC S3100V3 52TP EI LS 3100V3 52TP EI LS 3100V3 52TP EI GL S3100V3 10TP PWR EI LS 3100V3...

Страница 40: ...ported only by the S3100V3 18TP EI DC switch Rated voltage 48 VDC to 60 VDC Max voltage 36 VDC to 72 VDC Minimum power consumption 6 5 W 7 W 19 W Maximum power consumption 11 W 15 W 25 W Chassis leaka...

Страница 41: ...1 Melting current of power module fuse 2 A 250 V 3 15 A 125 V 3 15 A 250 V Cooling system Natural cooling without fan trays Natural cooling without fan trays Using fixed fan trays to draw ambient air...

Страница 42: ...oltage 54 VDC to 57 VDC Max voltage Single DC input 44 VDC to 60 VDC AC and DC inputs 54 VDC to 57 VDC DC input from a DC power supply system or an H3C RPS1600 A supported only by an S3100V3 20TP PWR...

Страница 43: ...ght side to draw ambient air in from the left side and exhaust heated air from the right side trays to draw ambient air in from the left side and the port side and exhaust heated air from the right si...

Страница 44: ...status LED SYS 6 10 100 1000BASE T autosensing Ethernet port LED 7 Console port 8 SFP port Figure2 2 Rear panel 1 Grounding screw 2 AC input power receptacle S3100V3 18TP EI Figure2 3 Front panel 1 10...

Страница 45: ...input power receptacle S3100V3 18TP EI DC Figure2 5 Front panel 1 10 100BASE T autosensing Ethernet port 2 10 100 1000BASE T autosensing Ethernet port 3 10 100BASE T autosensing Ethernet port LED 4 1...

Страница 46: ...System status LED SYS 7 Console port 8 SFP port Figure2 8 Rear panel 1 Grounding screw 2 AC input power receptacle S3100V3 28TP EI DC Figure2 9 Front panel 1 10 100BASE T autosensing Ethernet port 2...

Страница 47: ...E T autosensing Ethernet port 2 10 100BASE T autosensing Ethernet port LED 3 10 100 1000BASE T autosensing Ethernet port 4 10 100 1000BASE T autosensing Ethernet port LED 5 Console port 6 System statu...

Страница 48: ...e switching button 9 Console port 10 SFP port Figure2 14 Rear panel 1 AC input power receptacle 2 Grounding screw S3100V3 20TP PWR EI Figure2 15 Front panel 1 10 100BASE T autosensing Ethernet port 2...

Страница 49: ...port 2 10 100 1000BASE T autosensing Ethernet port 3 10 100BASE T autosensing Ethernet port LED 4 10 100 1000BASE T autosensing Ethernet port LED 5 SFP port LED 6 System status LED SYS 7 Mode LED MOD...

Страница 50: ...E T autosensing Ethernet port LED 4 System status LED SYS 5 RPS status LED RPS 6 Mode LED MODE 7 SFP port LED 8 10 100 1000BASE T autosensing Ethernet port LED 9 Port LED mode switching button 10 Cons...

Страница 51: ...Ethernet port specifications Item Specification Connector type RJ 45 Interface attributes 10 Mbps half full duplex 100 Mbps half full duplex MDI MDI X autosensing Max transmission distance 100 m 328...

Страница 52: ...qual to 80 km 49 71 miles make sure the operating temperature is lower than or equal to 40 C 104 F S3100V3 52TP EI S3100V3 20TP PWR EI S3100V3 20TP PWR EI DC N A S3100V3 28TP PWR EI GE SFP transceiver...

Страница 53: ...FP GE LH40 SM1310 1310 LC Single mode 9 125 N A 40 km 24 86 miles SFP GE LH40 SM1310 D 1310 LC Single mode 9 125 N A 40 km 24 86 miles SFP GE LH40 SM1550 1550 LC Single mode 9 125 N A 40 km 24 86 mile...

Страница 54: ...multimode 62 5 125 m multimode 2 km 1 24 miles SFP FE LX SM1310 A 1310 nm LC 9 125 m single mode 15 km 9 32 miles SFP FE LX SM1310 D 1310 nm LC 9 125 m single mode 15 km 9 32 miles SFP FE LH40 SM1310...

Страница 55: ...s LED The S3100V3 28TP PWR EI switch supports RPS input and provides an RPS status LED on the front panel to indicate the RPS operating status Table3 8 RPS status LED description LED mark Status Descr...

Страница 56: ...the autosensing Ethernet ports and the switch from different aspects Table3 11 10 100BASE T and 10 100 1000BASE T autosensing Ethernet port LED description Mode LED status Ethernet port LED status Des...

Страница 57: ...00 1000BASE T autosensing Ethernet ports LEDs on these switches Table3 12 10 100BASE T and 10 100 1000BASE T autosensing Ethernet port LED description LED status Description Steady green A link is pre...

Отзывы: