background image

 

1-9 

Table 1-11 S12500R chassis ordering information 

Product code 

Product name 

Description 

0235A2FL 

S12516R 

H3C S12516R Ethernet switch router chassis 

0235A2FN 

S12508R 

H3C S12508R Ethernet switch router chassis 

0235A2FM 

S12504R 

H3C S12504R Ethernet switch router chassis 

 

Содержание S12500R Series

Страница 1: ...H3C S12500R Switch Router Series Hardware Reference New H3C Technologies Co Ltd http www h3c com Document version 6W101 20201015...

Страница 2: ...H3C Technologies Co Ltd any trademarks that may be mentioned in this document are the property of their respective owners Notice The information in this document is subject to change without notice A...

Страница 3: ...s enclose syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a...

Страница 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...ions 1 1 Chassis views 1 1 Chassis components 1 2 Technical specifications 1 5 Weights and dimensions 1 5 Module power consumption and system power consumption 1 7 Heat dissipation 1 8 Environmental s...

Страница 7: ...ptimizes the CLOS switching fabric architecture and uses the variable cell based traffic scheduling and control forwarding mechanism to deliver higher forwarding efficiency more refined congestion con...

Страница 8: ...12508R Figure 1 3 S12504R Chassis components The device has an MPU section service module section power module section fan tray section and fabric module section The following figure uses the S12516R...

Страница 9: ...are below the service module slots No MPUs are provided with the device Purchase MPUs yourself The device has two MPU slots You can install one MPU or two MPUs for redundancy for the device To install...

Страница 10: ...stall two fan trays for the device to achieve redundancy Fabric module section Covered by the fan trays No fabric modules or fabric module slot filler panels are provided with the device Purchase fabr...

Страница 11: ...5 95 lb 39 8 mm 1 57 in 200 5 mm 7 89 in 411 0 mm 16 18 in LSXM2SFH16CR1 7 9 kg 17 42 lb 39 8 mm 1 57 in 853 0 mm 33 58 in 278 4 mm 10 96 in LSXM1SFH16ER1 9 7 kg 21 38 lb 39 8 mm 1 57 in 853 0 mm 33...

Страница 12: ...Depth PSR2400 54A 1 9 kg 4 19 lb 41 0 mm 1 61 in 100 0 mm 3 93 in 332 0 mm 13 07 in PSR2400 54D 1 9 kg 4 19 lb 41 0 mm 1 61 in 100 0 mm 3 93 in 332 0 mm 13 07 in PSR3000 54A 2 1 kg 4 63 lb 41 0 mm 1 6...

Страница 13: ...XM1SUP04TR1 24 W 35 W LSXM2SFH16CR1 194 W 308 W LSXM1SFH16ER1 487 W 816 W LSXM1SFH08CR1 84 W 135 W LSXM1SFH08DR1 159 W 255 W LSXM1SFH04DR1 86 W 140 W LSXM1CGQ36HBR1 608 W 1070 W LSXM1CGQ36HFR1 585 W 1...

Страница 14: ...ower consumption of the device is 2 52 2 608 6 194 2 187 2858 W The maximum system power consumption of the device is 2 70 2 1070 6 308 2 2570 9268 W Heat dissipation Heat dissipation is measured in B...

Страница 15: ...ring information Product code Product name Description 0235A2FL S12516R H3C S12516R Ethernet switch router chassis 0235A2FN S12508R H3C S12508R Ethernet switch router chassis 0235A2FM S12504R H3C S125...

Страница 16: ...lity matrixes 2 1 MPUs 2 1 Service modules 2 2 Fabric modules 2 3 Fabric module slot filler panels 2 4 Slide rails 2 4 Power modules 2 4 Fan trays 2 6 DC power cords 2 7 AC power cords 2 7 Chassis com...

Страница 17: ...ots Flash 4GB EMMC 8GB EMMC NVRAM 512 KB Port connector type RJ 45 LC USB Type A Mini USB Type AB RJ 45 LC USB Type A Ports One console port RJ 45 connector One console port Mini USB connector Two 10...

Страница 18: ...36 100 40 Gbps QSFP28 transceiver modules QSFP28 copper cables QSFP28 fiber cables QSFP transceiver modules QSFP copper cables QSFP fiber cables LSXM1CGQ 36HFR1 36 port 100GBASE QSFP28 Ethernet optic...

Страница 19: ...FP copper cables SFP fiber cables LSXM1CGQ 18QGHBR1 18 port 100GBASE Ethernet optical interface QSFP28 36 port 40GBASE Ethernet Optical interface module MPO LC 36 QSFP28 port 100 40 Gbps QSFP port 40...

Страница 20: ...stment range Occupied space S12516R 400 kg 881 83 lb LSXM1BSR 630 mm to 900 mm 24 80 in to 35 43 in 1 RU S12508R 220 kg 485 01 lb LSXM1BSR 630 mm to 900 mm 24 80 in to 35 43 in 1 RU LSTM2KSGD0 500 mm...

Страница 21: ...ge temperature 40 C to 70 C 40 F to 158 F Table 2 9 PSR3000 54A power module specifications Item Specifications Rated input voltage 100 to 240 VAC 50 or 60 Hz Rated output voltage 54 VDC Maximum input...

Страница 22: ...s H W D 41 100 332 mm 1 61 3 94 13 07 in Ambient temperature Operating temperature 10 C to 50 C 14 F to 122 F Storage temperature 40 C to 70 C 40 F to 158 F NOTE The power module shuts down automatica...

Страница 23: ...vice For the connector types of different countries or regions see H3C Power Cords Cables User Guide Chassis component ordering information To purchase chassis components contact the sales agent or H3...

Страница 24: ...Fan module for the H3C S12516R 0231A2UH LSXM108XFAN Fan module for the H3C S12508R 0231A2X9 LSXM104XFAN Fan module for the H3C S12504R 0231A4WX LSXM116XFANH High speed fan module for the H3C S12516R 0...

Страница 25: ...s LEDs 3 2 Module status LEDs 3 3 MPU active standby status LED 3 3 Service module LEDs 3 3 SFP port LEDs 3 3 QSFP port LEDs 3 4 QSFP28 port LEDs 3 4 Fabric module status LEDs 3 4 Fabric module status...

Страница 26: ...LEDs The following figure uses the LSXM1SUPER1 MPU for illustration Figure 3 1 LSXM1SUPER1 MPU LEDs 1 10 100 1000BASE T management Ethernet port LED LINK 2 10 100 1000BASE T management Ethernet port...

Страница 27: ...Off No link is present on the port Fan tray status LEDs An MPU provides one fan tray status LED to indicate the status of the fan trays For the description of the LED see Table 3 4 Table 3 4 Fan tray...

Страница 28: ...ered or the module is faulty Flashing red once every four seconds The temperature of the module is higher than the warning threshold or lower than the low temperature threshold Off The module is not i...

Страница 29: ...receiving or sending data On A link is present on a minimum of one channel Off No link is present QSFP28 port LEDs A LED is provided for each QSFP28 port to indicate the link status and data receivin...

Страница 30: ...the fabric module the fan tray covers from left to right On an S12504R fan tray the extend lines of the fabric module LED pairs correspond to the fabric module the fan tray covers from left to right...

Страница 31: ...Fan tray LED description OK FAIL Description On Off The fan tray is operating correctly Off On The fan tray is faulty Off Off The fan tray is not powered on Power module LEDs Each power module provide...

Страница 32: ...ent Output overvoltage Input under voltage Remote poweroff Orange An over temperature alarm occurred on the power module PSR3000 54AHD IN Off No power is being input The power module is in self protec...

Страница 33: ...s 4 2 Cable type 4 2 Pin assignments 4 4 Making an Ethernet twisted pair cable 4 5 Optical fiber 4 5 Optical fiber 4 5 Optical fiber cable 4 6 Patch cord 4 6 Pigtail cord 4 6 Fiber connector 4 6 Preca...

Страница 34: ...nects SFP ports to transmit data QSFP copper cable QSFP ports Connects QSFP ports to transmit data QSFP28 copper cable QSFP28 ports Connects QSFP28 ports to transmit data QSFP to SFP copper cable QSFP...

Страница 35: ...green stripe pin 2 green solid pin 3 white orange stripe pin 4 blue solid pin 5 white blue stripe pin 6 orange solid pin 7 white brown stripe pin 8 brown solid Standard 568B pin 1 white orange stripe...

Страница 36: ...ssified into straight through and crossover cables based on their pinouts Straight through The pinouts at both ends comply with standard 568B as shown in Figure 4 3 Crossover The pinouts at one end co...

Страница 37: ...Receive data BIDB Bi directional data cable B 4 Reserved N A BIDC Bi directional data cable C 5 Reserved N A BIDC Bi directional data cable C 6 Rx Receive data BIDB Bi directional data cable B 7 Rese...

Страница 38: ...enabled on a port Making an Ethernet twisted pair cable 1 Cut the cable to length with the crimping pliers 2 Strip off an appropriate length of the cable sheath The length is typically that of the RJ...

Страница 39: ...nal routing Patch cords fall into single mode and multi mode patch cords Single mode patch cord The jacket is yellow It permits transmission over longer distances Multi mode patch cord The jacket is o...

Страница 40: ...he fiber port Never bend or curve a fiber when connecting it After a fiber is installed well the bend radius must be not less than 40 mm the minimum dynamic bend radius is 20 D and the minimum static...

Страница 41: ...r cable You can use QSFP copper cables to connect the QSFP ports Figure 4 8 QSFP copper cable 1 Connector 2 Pull latch QSFP28 copper cable You can use QSFP28 copper cables to connect the QSFP28 ports...

Страница 42: ...ble A QSFP to SFP copper cable is a cable with one QSFP module at one end and four SFP modules at the other end Figure 4 10 QSFP to SFP copper cable 1 QSFP connector 2 QSFP pull latch 3 SFP connector...