The Extended BootWare is self-decompressing...........................Done. 

 

**************************************************************************** 

*                                                                          * 

*                   H3C  S12500  BootWare,  Version  1.01                      * 

*                                                                          * 

**************************************************************************** 

Compiled  Date       :  Mar  27  2013 

CPU  Type              :  P5040 

CPU  L1  Cache          :  32KB 

CPU  L2  Cache          :  1024KB 

CPU  Clock  Speed       :  1800MHz 

Memory  Type           :  DDR3  SDRAM 

Memory  Size           :  8192MB 

Memory  Speed          :  1066MHz 

BootWare  Size         :  8MB 

Flash  Size            :  512MB 

cfa0  Size             :  4002MB 

NVRAM  Size            :  1024KB 

BASIC  CPLD  Version    :  001C 

EXTENDED CPLD Version : 001C 

PCB  Version           :  Ver.A 

 

 

Board self testing........................... 

Board  steady  testing...                           [  PASS  ] 

Board  SlotNo...                                     [   0  ] 

DX246  testing...                                   [  PASS  ] 

PHY88E1111  testing...                             [  PASS  ] 

CPLD1  testing...                                    [  PASS  ] 

CPLD2  testing...                                    [  PASS  ] 

NS16550  register  testing...                       [  PASS  ] 

The  switch's  Mac  address...                       [00:0F:E2:0E:08:03] 

CF  Card  testing...                                  [  PASS  ] 

BootWare Validating... 

Press Ctrl+B to access EXTENDED-BOOTWARE MENU... 

# Press 

Ctrl

+

B

 at prompt to access the EXTEND-BOOTWARE menu. 

Password recovery capability is enabled. 

Note: The current operating device is cfa0 

Enter < Storage Device Operation > to select device. 

 

==========================<EXTENDED-BOOTWARE MENU>========================== 

|<1>  Boot  System                                                                     | 

|<2>  Enter  Serial  SubMenu                                                          | 

|<3>  Enter  Ethernet  SubMenu                                                        | 

|<4>  File  Control                                                                    | 

|<5>  Restore  to  Factory  Default  Configuration                                  | 

|<6>  BootWare  Operation  Menu                                                       | 

Содержание S12500 Series

Страница 1: ...gzhou H3C Technologies Co Ltd All rights reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co Ltd...

Страница 2: ...evice as a TFTP client to upgrade software 3 Example Using the device as an FTP client to upgrade software 7 Example Using the device as an FTP server to upgrade software 11 Upgrading software from th...

Страница 3: ...Configuration restrictions and guidelines When you upgrade software follow these restrictions and guidelines Make sure the device has sufficient storage space for the upgrade file If the device does...

Страница 4: ...bytes press CTRL_C to break Reply from 192 168 100 14 bytes 56 Sequence 0 ttl 128 time 2 ms Reply from 192 168 100 14 bytes 56 Sequence 1 ttl 128 time 1 ms Reply from 192 168 100 14 bytes 56 Sequence...

Страница 5: ...NE Absent NONE 17 NONE Absent NONE 18 NONE Absent NONE The output shows that the device has two MPUs one active MPU in slot 0 and one standby MPU in slot 1 You must upgrade both MPUs Use TFTP to downl...

Страница 6: ...10 SYSTEM old bin slot 1 backup This command will set the backup startup software images Continue Y N y The images that have passed all examinations will be used as the backup startup so ftware images...

Страница 7: ...255 255 255 0 Example Using the device as an FTP client to upgrade software Network requirements As shown in Figure 3 use FTP to download a software upgrade file from an FTP server to upgrade the devi...

Страница 8: ...the FTP server Device system view Device interface M GigabitEthernet0 0 0 Device M GigabitEthernet0 0 0 ip address 192 168 100 66 255 255 255 0 Device M GigabitEthernet0 0 0 quit Device quit Verify t...

Страница 9: ...CMW710 R7328P01 2 NONE Absent NONE 3 LST1GT48LEC1 Normal s12500 CMW710 R7328P01 4 NONE Absent NONE 5 NONE Absent NONE 6 NONE Absent NONE 7 NONE Absent NONE 8 NONE Absent NONE 9 NONE Absent NONE 10 NO...

Страница 10: ...CMW710 SYSTEM test bin slot 1 main This command will set the backup startup software images Continue Y N y The images that have passed all examinations will be used as the main startup so ftware image...

Страница 11: ...software images flash s12500 cmw710 boot test bin flash s12500 cmw710 system test bin Backup startup software images flash s12500 cmw710 boot old bin flash s12500 cmw710 system old bin Display the cur...

Страница 12: ...reboot If the device has two MPUs you must upgrade both MPUs for the device to operate correctly You must set the file transfer mode to binary Configuration procedures 1 Configure the FTP server Assig...

Страница 13: ...ready User 192 168 100 66 none abc 331 Password required for abc Password 230 User logged in Access the directory that contains the upgrade file ftp lcd E Local directory now E Set the file transfer...

Страница 14: ...OOT test bin Done Decompressing file S12500 CMW710 SYSTEM test bin to cfa0 S12500 CMW710 SYSTEM test bin Done This command will set the main startup software images Continue Y N y The images that have...

Страница 15: ...ystem image version 7 1 045 Release 7328P02 Compiled Jul 28 2014 17 32 35 More 2 Verify that the software images on the MPUs are the same Display the current software images and startup software image...

Страница 16: ...wn in Figure 6 upgrade software from the BootWare menu Download software images from a TFTP server Figure 6 Network diagram Software version used This configuration example was created and verified on...

Страница 17: ...MPU to the host Details not shown Run the HyperTerminal and then create a connection Figure 7 Creating a connection In the Connect To dialog box select COM1 for Connect Using and then click OK Figure...

Страница 18: ...erties The user view prompt is displayed if you access the CLI successfully Figure 10 User view prompt at the CLI 2 Configure the TFTP server Assign the IP address 192 168 100 14 24 to the TFTP server...

Страница 19: ...Switch system view Switch version check ignore Save the configuration Switch save The current configuration will be written to the device Are you sure Y N y Please input the file name cfg flash start...

Страница 20: ...ting PASS Board SlotNo 0 DX246 testing PASS PHY88E1111 testing PASS CPLD1 testing PASS CPLD2 testing PASS NS16550 register testing PASS The switch s Mac address 00 0F E2 0E 08 03 CF Card testing PASS...

Страница 21: ...r choice 0 5 5 ETHERNET PARAMETER SET Note Clear field Go to previous field Ctrl D Quit Protocol FTP or TFTP tftp Load File Name s12500 ipe Target File Name s12500 ipe Server IP Address 192 168 1 100...

Страница 22: ...date Backup Image File 4 Download Files 5 Modify Ethernet Parameter 0 Exit To Main Menu Ensure The Parameter Be Modified Before Downloading Enter your choice 0 5 Enter 2 in the Ethernet submenu to upg...

Страница 23: ...u to boot the standby MPU Loading the main image files Loading file cfa0 S12500 CMW710 SYSTEM R7328P02 bin Done Loading file cfa0 S12500 CMW710 BOOT R7328P02 bin Done Image file cfa0 S12500 CMW710 BOO...

Страница 24: ...ware images on slot 0 Current software images cfa0 s12500 CMW710 BOOT R7328P02 bin cfa0 s12500 CMW710 SYSTEM R7328P02 bin Main startup software images cfa0 s12500 CMW710 BOOT R7328P02 bin cfa0 s12500...

Отзывы: