5-17
Enter your choice(0-3): 3
Chassis ID has been changed to 2.
The current chassis ID is 2.
Modifying system working mode
Follow these steps to modify the system working mode through the BootWare menu:
Step1
Select
9
in the BootWare menu to enter the product special operation submenu.
===========================<EXTEND-BOOTWARE MENU>=========================
|<1> Boot System |
|<2> Enter Serial SubMenu |
|<3> Enter Ethernet SubMenu |
|<4> File Control |
|<5> Modify BootWare Password |
|<6> BootWare Operation Menu |
|<7> Clear Super Password |
|<8> Storage Device Operation |
|<9> Product Special Operation |
|<0> Reboot |
==========================================================================
Enter your choice(0-9): 9
========================<PRODUCT SPECIAL OPERATION>=========================
|<1> Modify Chassis ID Operation |
|<2> Modify Working Mode |
|<3> Modify PCL Key |
|<4> Skip Current System Configuration |
|<0> Exit To Main Menu |
============================================================================
Step2
Select
2
to enter the submenu for modifying the system working mode.
Enter your choice(0-1): 2
=============================<WORKING MODE SET>=============================
|Note:'*'indicates the current working mode |
| Change The Working Mode Accordingly |
|-------------------------<Working Mode Avaliable>-------------------------|
|<1> Standard Mode* |
|<2> BridgeE Mode |
|<3> RouteE Mode |
|<4> Advance Mode |
|<5> Configurable Mode |
|<0> Exit |
============================================================================
Step3
Select the working mode of the system. The asterisk (*) marks the current working mode. Currently, the
Advance Mode
and
Configurable Mode
are not supported. For details about the system working
modes, see
Device Management Configuration
in the
System Volume.
Enter your choice(0-5): 2
=============================<WORKING MODE SET>=============================