background image

 

10 

Figure 7 Securing the power cord with a straight entry C19 
connector by using an self-adhesive cable tie 

 

 

3. 

Plug the other end of the power cord into an AC power 
receptacle, and turn on the circuit breaker. 

4. 

Verify that the power input LED is ON. If the LED is on, the 
power cord is correctly connected. If the LED is OFF, 
troubleshoot the installation process. 

Removing a power module 

To avoid device damage and bodily injury, follow the procedures 
in

 Figure 8

 to remove the power module. 

Содержание PSR2400-54A

Страница 1: ...H3C PSR2400 54A Power Module User Manual New H3C Technologies Co Ltd http www h3c com Document version 6PW105 20181116 ...

Страница 2: ... subject to change without notice All contents in this document including statements information and recommendations are believed to be accurate but they are presented without warranty of any kind express or implied H3C shall not be liable for technical or editorial errors or omissions contained herein Environmental protection This product has been designed to comply with the environmental protect...

Страница 3: ...ecifications 3 Power module configuration 4 Installing and removing the power module 5 Installing the power module 5 Installing the power module 5 Connecting the power cord 8 Removing a power module 10 Removing the power cord 11 Removing the power module 11 ...

Страница 4: ...ltage output short circuit output undercurrent output overcurrent and overheat Redundancy The power modules can operate in N 1 or N N redundancy For more information see Power module configuration Hot swapping You can install or remove a power module when the device is operating The power module shuts down automatically when its temperature exceeds the acceptable range When the temperature returns...

Страница 5: ...2 Front panel Figure 1 Front panel 1 Power input LED AC OK 2 Handle 3 AC input receptacle 4 Latch 5 Power output LED DC OK 6 Air outlet vents LEDs The PSR2400 54A power module has two LEDs 1 2 6 3 4 5 ...

Страница 6: ...ccurred for example output short circuit output overcurrent output overvoltage output undervoltage or remote shutdown The power module has entered self protection mode Orange High temperature NOTE After the circuit breaker of the power module is switched off the LEDs on the power module will remain on for a while Technical specifications Table 3 Technical specifications Item Specifications Rated i...

Страница 7: ... actual power consumption the power module slot number and power redundancy design Determine the power module redundancy design based on the power source conditions When two mains power inputs are provided you can configure the power modules in N N redundancy N N must be not greater than the total number of power module slots When one mains power input is provided you can configure the power modul...

Страница 8: ...low the procedures in Figure 2 to install a power module Figure 2 Power module installation procedure Before the installation prepare an ESD wrist strap and a flat blade screwdriver yourself Installing the power module 1 Wear an ESD wrist strap and make sure the strap makes good skin contact and is reliably grounded ...

Страница 9: ...shown in Figure 3 thread the flat blade screwdriver through the hole in the handle of the blank panel and pull the blank panel out If the blank panel is as shown in Figure 4 put your forefinger in the hole in the blank panel and pull the blank panel out Figure 3 Removing a blank panel 1 ...

Страница 10: ...tch is below the handle 5 Holding the handle of the power module with one hand and supporting the bottom of the power module with the other slide the power module along the guide rails into the slot until you hear a click The power module is foolproof If the power module is oriented incorrectly you cannot install the power module into the slot If you encounter a hard resistance while inserting the...

Страница 11: ...2400 54A XC for sale The power cord shipped with the power module depends on the product code For product code PSR2400 54A the power cord uses a 16A AC power cord with a C19 angled connector shown in Figure 6 For product code PSR2400 54A XC the power cord uses a 16A AC power cord with a C19 straight connector shown in Figure 7 You can also prepare yourself a 16A AC power cord with a C19 angled or ...

Страница 12: ...vable cable tie or self adhesive cable tie to secure the power cord to the handle of the power module Route the power cords of the left power modules to the left side Route the power cords of the right power modules to the right side Figure 6 Securing the power cord with a C19 angled connector by using a removable cable tie ...

Страница 13: ... cord into an AC power receptacle and turn on the circuit breaker 4 Verify that the power input LED is ON If the LED is on the power cord is correctly connected If the LED is OFF troubleshoot the installation process Removing a power module To avoid device damage and bodily injury follow the procedures in Figure 8 to remove the power module ...

Страница 14: ...rn off the circuit breaker of the power cord 2 Wear an ESD wrist strap and make sure the strap makes good skin contact and is correctly grounded 3 Remove the cable tie and pull the power cord out Removing the power module CAUTION Before you insert a removed power module into a power module slot make sure the LEDs on the power module are off ...

Страница 15: ... out of the slot 2 As shown in Figure 9 grasping the handle of the power module with one hand and supporting the bottom of the power module with the other hand pull the module slowly along the guide rails out of the slot Figure 9 Removing a power module 3 Place the power module on an antistatic mat 4 Install the blank panel in the power module slot ...

Отзывы: