65
optical fiber to the peer ends. Make sure the Rx and Tx ports on the transceiver module are
connected to the Tx and Rx ports at the peer end, respectively.
MPO connector
—Orient the connector with the white spot on it facing right. Insert the MPO
fiber connector horizontally into the transceiver module. Push the MPO fiber connector into
the transceiver module slightly until it clicks into place.
8.
Use cable ties at a spacing of 150 mm (5.91 in) to bind optical fibers.
9.
Label optical fibers according to the cable labeling specifications.
Connecting an E1 interface cable
Appearance of the 4E1/8E1 splitter cable
Figure 64 4E1 splitter cable
Figure 65 8E1 splitter cable
Connecting the cable
When connecting the interface cable, pay attention to the mark on the interface to avoid wrong
insertion, which might damage the interface module or even the host.
DB68
BNC
DB68
BNC